| Product Name | AE-30F Photoelectric colorimeter |
| Brand | Erma |
| Model | AE-30F |
| Origin | China |
| Filter | Glass:420, 470, 530, 620, 660nm |
| Indication | 3-digits LED |
| Scale | Absorbancy 0 to -2LogT |
| Detector | Silicon Poto Diode |
| Light Source | 6V 0.5A Tungsten Lamp |
| Glass Test Tube | 12mm φ X 105mm, 10mm φ inner dia. |
| Drain-Cell | 10mm φ inner dia |
| Final Sample volume | 1mℓ (Test Tube) 2.5mℓ (Drain-Cell) |
| Power Supply | 110V 10VA or 220V 20VA |
| Dimensions (Main body) | 250(W)x330(D)x145(H) |
| Net Weight (Main body) | 3.5kg |
| Product Name | ESR Machine |
| Brand | Mindray |
| Application | Blood Sedimentation Rate Analysis |
| Loading Capacity : | Maximum 10 samples |
| Loading Pattern : | Random Access |
| Reading chambers | 2 10 (ten) |
| Analytical capacity : | Maximum 20 tests/hour |
| Loading Capacity : | Maximum 10 samples at a time |
| Analysis time : | 30 minutes |
| Throughput : | 20 specimens per hour |
| Results : | In Westergren mm/hour (by interpolation |
| Test Tube : | 1.1 ml -1.28 ml blood |
| Temperature correction : | Results autocorrected to 18 °C |
| (Manley method) | |
| Measurement principle : | Infrared (IR) detection |
| Product Name | Blood Gas Electrolyte Analyzer |
| Brand | Radiometer, Denmark |
| Model | ABL80 |
| Usage/Application | Hospital |
| Assays | blood gas, electrolyte, and lactate |
| Operation Mode | Automatic |
| Frequency | 50/60 Hz |
| Chamber Type | Single |
| Product name | binocular biological microscope |
| Model | XSZ-107BN |
| Total Magnification | 40X~1600X |
| Eyepieces | WF10X(2PCS), WF16X(2PCS) |
| Objectives | 4X, 10X,40XS, 100XS |
| Eyepieces Tube | Binocular 45º. inclined Tube Rotatable 360º . |
| illumination | 6V/20W Halogen Lamp |
| Coarse Adjustment Range | 30mm |
| Fine Adjustment Range | 30mm |
| Working Stage | Double Layer Mechanical Stage:130×140mmMoving Range 75mm×45mm |
| Condenser | NA1,25 Abee Condenser With Changeable Diaphragm, Moving Scale And Fil |
| Brand | Rayto |
| Model | Chemray 120 |
| Origin | Guangdong, China (Mainland) |
| Type | Biochemical Analysis System |
| Product Name | Bio-Chemistry analyzer Machine |
| Brand | Bio-Check |
| Model | BC-9200Exp |
| Origine | USA |
| Absorbance range | 0.500-3.00abs |
| Light source | Halogen lamp |
| Wavelength accuracy | ≤±0.01A |
| Filters | 340,405,500,546,620nm,(3 more optional filters) |
| Resulation | 0.001 Abs(SISPLAYYED),0.0001ABS |
| Cross-contamination | 8nm1% |
| Interface | RS-232 Seroa;cab;e |
| Display | LCD |
| Flow cell | Metal – quartz flow cell |
| Temperature control | 25 30 + and ambient temperature |
| Output | Internal or external printer |
| Dimensions | 360mm × 318mm × 160mm |
| Weight | 7kg |
| Power Supply | AC 100V-240V + 10 % 50-60Hz |
| Plate Type | 96/48 -well plate |
| Display | 7″ TFT LCD Display |
| Wavelength Range | 400 to800 nm |
| Standard Wavelength | 405, 450, 492, 630 nm & 4 Optional |
| Wavelength Accuracy | 0.008A |
| Resolution | 0.001 Abs |
| Reading Speed | 3s< single wavelength, Double Wavelength 6s< |
| Reading Range | 0.000-4.000 Abs |
| Stability | ±0.03 A |
| Measurement System | 8 Channel Optical System |
| Shaking | Linear (slow, medium and high mode) |
| Printer | Built-In Thermal Printer, Optional External Printer |
| Power Supply | 100-240 V, 50-60 Hz |
| Weight (Net/Gross) | 11.5 kg |
| Name | Cardio Chek Plus Professional Analyser |
| Test(s) available | Total cholesterol; HDL cholesterol; LDL cholesterol; triglycerides; glucose; ketones; and creatinine |
| Sample type | Blood |
| Measuring range | Quantitative (mmol/L) |
| Pack size | N/A |
| Sample size/volume | 15 – 40 µL |
| Testing time | 1.5 minutes |
| Quality control | Yes (external Multi-chemistry two levels: high and low; HDL two levels: high and low) |
| Storage | Room temperatur |
| Name | Cardio Chek Professional Analyser |
| Test(s) available | Total cholesterol; HDL cholesterol; LDL cholesterol; triglycerides; glucose; ketones; and creatinine |
| Sample type | Blood |
| Measuring range | Quantitative (mmol/L) |
| Pack size | N/A |
| Sample size/volume | 15 – 40 µL |
| Testing time | 2 minutes |
| Quality control | Yes (external Multi-chemistry two levels: high and low; HDL two levels: high and low) |
| Storage | Room temperature |
| Classification | Laboratory Centrifuge |
| Brand Name | Yongjing |
| Model Number | 800 |
| Place of Origin | Zhejiang, China |
| Max speed | 4000rpm |
| Max capacity |
6*20ml |
| Instrument Name | Biochemistry Analyzer |
| Model | Chem 7 |
| Usage/Application | Bio-Chemistry, Clinical Chemistry |
| Brand | Erba |
| Parameters | Around 100 |
| Automation | Semi-Automatic |
| Operation Mode | Semi-Automatic |
| User Input | Keypad |
| Power Supply | 220v |
| Display | Digital |
| Storage | 2000 |
| Minimum Order Quantity | 1 |
| Product Name | Water Bath |
| Brand | Digisyestem |
| Model | DSB-1000D |
| Capacity | 20 Liters |
| Inner tank dimension | W490xD290xH150mm |
| Temperature setting | Digital |
| Temperature readout | Digital |
| Temperature control | PID |
| Temperature sensor | PT100Ω |
| Stability | ±0.2℃ |
| Working temperature range | Ambient +5℃ ~100℃ |
| Power watts | 1200W |
| Optional accessory | Flat lid, gable cover, external equipment, test tube rack |
| Weight (kg) (N.W./G.W.) | 10.0/11.5 |
| Overall dimension | W540xD340xH190mm |
| Power supply | AC 110V 50/60Hz (220V 50/60Hz available) |
| Testing channel: | 1 channel |
| Sample incubation positions: | 5 |
| Reagent incubation positions: | 2 |
| Software timer: | 1 |
| Test wavelength: | 470nm |
| Sample volume: | 20uL-40ul |
| Reagent volume: | 20uL-40ul |
| Temp control precision: | 37±0.3℃ |
| Memory: | 10,000 test results |
| Notation of Result: | S, %, PTR, INR, g/L |
| Display: | LCD (192*64) |
| Output: | Built-in thermal printer |
| Input: | Keypad |
| Interface: | RS-232 |
| Power supply: | AC220V±15%, 50-60Hz |
| Working Condition: | Temperature 10℃-30℃, Humidity ≤80% |
| Dimension: | 270*270*115mm (L*W*H) |
| Net Weight: | 5Kg |
| Testing channel: | 2 channels |
| Analysis mode: | 2 different parameters analysis in the same time |
| Sample incubation positions: | 16 |
| Reagent incubation positions: | 4 |
| Software timer: | 2 |
| Test wavelength: | 470nm |
| Sample volume: | 20uL-40ul |
| Reagent volume: | 20uL-40ul |
| Temp control precision: | 37±0.3℃ |
| Memory: | 10,000 test results |
| Notation of Result: | S, %, PTR, INR, g/L |
| Display: | LCD (240*128) |
| Output: | Built-in thermal printer |
| Input: | Keypad |
| Interface: | RS-232 |
| Power supply: | AC220V±15%, 50-60Hz |
| Working Condition: | Temperature 15℃-30℃, Humidity ≤90% |
| Dimension: | 395*320*135mm (L*W*H) |
| Net Weight: | 6Kg |
| Product Name | Urine Analyzer |
| Model | BC 400 |
| Brand | Contec |
| Testing items | GLU, BIL, SG, KET, BLD, PRO, URO, NIT, LEU, VC, PH. |
| Testing theory | RGB tricolor testing theory. |
| Repetition | CV≤ 1%. |
| Stability | CV≤ 1%. |
| Display | 2.8″ color LCD. |
| Working mode | One-Step, Slowly-Series, and Quickly-Series testing mode. |
| Testing speed | 120 pieces/hour or 60 pieces/hour. |
| Data storage | Storage of 1000 test items, freely query in term of testing time and sample number. |
| Printer | Built-in high-speed thermal printer. |
| Interface | Standard RS-232 intercommunication interface. |
| Power supply | 100~240V, 50/60Hz. |
| Dimension | 240mm(L) x 220mm(W) x 130mm(H). |
| Weight | About 1.8Kg. |
| Technical Specification | |
| Speed: | Swing: 0-80 times/min |
| Rolling: | 0-80 r/m |
| Swing amplitude: | 22±1mm |
| Power rating: | 12W |
| Voltage: | 220V±10% (50Hz) |
| N.W.: | 3.6kg |
| External dimension: | 394×266×98mm |
| Normal Packing: | 2 sets/package |
| Package measurement: | 490x360x420mm |
| Package | N.W.: 9.4KG |
| Package | G.W.: 12.5KG |
| Technical Specification | |
| Model | LF-400 |
| Max. speed | 4000r/min |
| Max. RCF | 2325×g |
| Angel rotor capacity | 10ml x12 |
| Running mode | Step-adjusted speed |
| Time setting range | 0~30min |
| Power supply | AC220V/50Hz, AC110V/60Hz |
| Dimension | 280×310×265mm(L×W×H) |
| Weight N./G. | 9Kg / 10kg |
| Technical Specification | |
| Rotation Speed: | 12-32 r/m |
| Tube Qty: | 1-24 pcs |
| Tube diameter: | Ø13±0.1mm |
| Plate Diameter: | Ø300mm |
| Angle of Inclination: | 38º |
| Voltage: | 220V±10% (50Hz) |
| Power Rating: 12W | 12W |
| Operation mode: | continuous |
| Normal Packing: | 2 sets/package |
| Package measurement: | 670x380x380mm |
| Package | N.W.: 9KG |
| Package | G.W.: 10.8KG |
| Product Name | DIFFERENTIAL BLOOD CELL COUNTER | ||
| Brand | Digisyestem | ||
| Model | DBC-2 | DBC-6 | DBC-9 |
| Number of Keys | 2 | 5 | 8 |
| Totalizer | No | Yes | Yes |
| Figure range | 0~999 | 0~999 | 0~999 |
| Dimension (LxWxH) | 100×80×50 | 250×80×50 | 320×80×50 |
Biocare IE-12A 12 Channel ECG Machine