| Technical Specification | |
| Rotation Speed: | 12-32 r/m |
| Tube Qty: | 1-24 pcs |
| Tube diameter: | Ø13±0.1mm |
| Plate Diameter: | Ø300mm |
| Angle of Inclination: | 38º |
| Voltage: | 220V±10% (50Hz) |
| Power Rating: 12W | 12W |
| Operation mode: | continuous |
| Normal Packing: | 2 sets/package |
| Package measurement: | 670x380x380mm |
| Package | N.W.: 9KG |
| Package | G.W.: 10.8KG |
| Product Name | DIFFERENTIAL BLOOD CELL COUNTER | ||
| Brand | Digisyestem | ||
| Model | DBC-2 | DBC-6 | DBC-9 |
| Number of Keys | 2 | 5 | 8 |
| Totalizer | No | Yes | Yes |
| Figure range | 0~999 | 0~999 | 0~999 |
| Dimension (LxWxH) | 100×80×50 | 250×80×50 | 320×80×50 |
| Product Name | Biological Microscope |
| Brand | Optima Digisystem |
| Model | G-302 |
| Observation tube | Binocular head inclined at 30˚ |
| Interpupillary distance | From 55-75mm |
| Focusing | Coaxial focusing knob, coarse focusing range is 30mm and fine focusing is graduated in increment of 2μm |
| Stage | Large mechanical stage with size 140 x 140mm, X-Y travel is 50 x 75mm with graduation of 0.1mm |
| Eyepiece | WF10X/18 |
| Objective | Achromatic 4X, 10X, 40X (spring), 100X (spring) oil(Plan achromatic objectives are available) |
| Condenser | N.A. 1.25 Abbe condenser with iris diaphragm and filter holder |
| Illumination | 6V20W halogen lamp with adjustable light intensity |
| Power supply | 110/220V switchable |
| Standard accessories | Dust cover, immersion oil, blue and green filters, backup lamp, plano-concave mirror |
| Optional accessories | WF10X/18 eyepiece with 10/100mm scale, EW10X/20 or WF16X eyepiece, PL 2.5X objective, achromatic 20X or 60X objective, quintuple nosepiece, swing-out condenser, simple polarization attachment, simple Koehler illumination attachment, phase-contrast attachment |
| 2pieces handpiece |
| 3 pieces sucker (air + water + electronic) |
| 2 piece 3-way syringes. Glass type patient tray |
| Tissue box |
| Censor & manual system halogen light |
| Extra tray cover |
| Extra unit cover |
| 2 side operating system |
| Hydraulic doctor’s tool |
| Specifications | |
| ECG | |
| Lead type | 3-lead or 5-lead selectable |
| Lead selection, 3-lead | I, II, III |
| Lead selection, 5-lead | I, II, III, aVR, aVL, aVF, V |
| HR measurement | Adult / pediatric: 15 bpm – 300 bpm Neonatal: 15 bpm – 300 bpm Step: 1 bpm |
| HR accuracy | ±5 bpm or ±1 %, whichever is greater |
| Arrhythmia | 21 calls |
| ST measurement range | -2.5 mV – +2.5 mV |
| Waveform speed | 6.25 mm/s,12.5 mm/s, 25 mm/s, 50 mm/s |
| Gain selection | x 1/4, x 1/2, x 1, x 2, x 4, Auto |
| Pacemaker detection | Yes |
| Protection | Against electrosurgical interference and defibrillation |
| Non-invasive blood pressure (NBP) | |
| Method | Automatic oscillometric |
| Parameters | SYS/DIA/MAP/Pulse Rate |
| Operating mode | Manual/Auto/STAT |
| Auto measure intervals | 3, 5, 10, 15, 30, 60, 90, 120, 240, 480 minutes |
| Units | mmHg/kPa |
| Cuff pressure range, adult / pediatric | 0 – 300 mmHg ( 0 kPa – 40.0 kPa) |
| Cuff pressure range, neonate | 0 – 150 mmHg ( 0 kPa – 20.0 kPa) |
| Systolic measurement range, adult/ pediatric | 30 mmHg – 254 mmHg (4.0 kPa – 33.9 kPa) |
| Systolic measurement range, neonate | 30 mmHg – 135 mmHg (4.0 kPa – 18.0 kPa) |
| Diastolic measurement range, adult / pediatric | 10 mmHg – 220 mmHg (1.3 kPa – 29.3 kPa) |
| Diastolic measurement range, neonate | 10 mmHg – 110 mmHg (1.3 kPa – 14.7 kPa) |
| MAP measurement range, adult / pediatric | 20 mmHg – 235 mmHg (2.7 kPa – 31.3 kPa) |
| MAP measurement range, neonate | 20 mmHg – 125mmHg (2.7 kPa – 16.7kPa) |
| Accuracy, maximum standard deviation | 8 mmHg (1.1 kPa) |
| Accuracy, mean error | ±5 mmHg (±0.7 kPa) |
| Pulse rate range | 40 bpm – 240 bpm |
| Pulse rate accuracy | ±5bpm or ±5%, whichever is greater |
| SpO2 (Philips SpO2 technology) | |
| Measurement range | 0 – 100 % |
| Accuracy | 70 % – 100 %, depends on sensor; 0 – 69 %, unspecified |
| Waveform speed | 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s |
| Pulse rate range | 30 bpm – 300 bpm |
| Pulse rate accuracy | ±2 bpm or ±2%, whichever is greater |
| Perfusion index | Yes |
| Respiration (RESP) | |
| Measurement method | Thoracic impedance |
| Measurement range | 0 rpm – 150 rpm |
| Accuracy | 0rpm – 120rpm: ±1 rpm; 121rpm – 150rpm: ±2 rpm |
| Waveform speed | 6.25 mm/s,12.5 mm/s, 25 mm/s, 50 mm/s Accuracy undefined |
| Gain selection | x 1/2, x 1, x 2 |
| Apnea alarm | Yes, 10 – 60 s |
| Work mode | Auto or manual (threshold) |
| RESP lead | RA-LL |
| Temperature (TEMP, 2-channel) | |
| Measurement range | 0 – 50℃ (32℉ – 122℉) |
| Resolution | 0.1℃ (0.2℉) |
| Accuracy | ±0.1℃ (±0.2℉) (without sensor) |
| Units | ℃ / ℉ |
| Minimum measuring time | Attachable skin surface probe: less than 10 minutes Esophageal/rectal probe: less than 2 minutes |
| Capnopgraphy (etCO2, optional) | |
| Method | Microstream, infrared absorption (Oridion) |
| Parameters | awRR, etCO₂, inCO₂ |
| Measurement range | 0 – 99 mmHg (0 kPa – 13.2 kPa) |
| Accuracy+C781, 0 – 38 mmHg (0 kPa – 5.1 kPa) | ±2 mmHg (±0.28 kPa) |
| Accuracy, 39 mmHg – 99 mmHg (5.2 kPa – 13.2 kPa) | ± (5% of reading + 0.08% for every 1 mmHg (0.13 kPa) above 38 mmHg (5.1kPa) |
| awRR range | 0-150 rpm |
| awRR accuracy, 3 rpm – 70 rpm | ±1 rpm |
| awRR accuracy, 71 rpm – 120 rpm | ±2 rpm |
| awRR accuracy, 121 rpm – 150 rpm | ±3 rpm |
| Invasive Blood Pressure | |
| Accuracy | ±4 mmHg (0.53 kPa) or ±4 % of reading, whichever is greater |
| Invasive blood pressure (IBP, 2-channel, optional) | |
| Parameters | SYS/DIA/MAP/Pulse Rate |
| Measurement range | -50 – 400 mmHg (-6.6 kPa – 53.3 kPa) |
| Waveform speed | 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s |
| Resolution | 1 mmHg (0.13 kPa) |
| Units | mmHg/kPa/cmH₂O |
| Transducer sensitivity | 5 uV/V/mmHg |
| Pulse rate range | 30 bpm – 254 bpm |
| Pulse rate accuracy | ±2bpm or ±2%, whichever is greater |
| Sampling rate | 62.5 samples per second |
| Recorder (optional) | |
| Type | Built-in thermal recorder, 3 channels |
| Print mode | Real-time recording, timed recording, alarm-activated recording |
| Print speed | Auto, 12.5 mm/s, 25 mm/s, 50 mm/s |
| Display | |
| Type | Color TFT LCD, 4:3 |
| Size | 10.4+611:631″ |
| Resolution | 800 x 600 pixels |
| Channels | Max 11 channels (auto waveform channel height adjustment) |
| Power supply | |
| AC power input | 100 – 240 VAC, 50/60 Hz |
| Battery | Rechargeable Li-Ion battery Maximum 2.5 hour continuous monitoring (1 battery) |
| Weight and dimensions | |
| Net weight | Approx. 3.5 kg without battery |
| Dimensions (w x d x h) | 316 mm x 265 mm x 131 mm (12.5 in. x 10.5 in. x 5.2 in.) |
| Safety approval and quality system | |
| Safety standard | IEC 60601-1-2:2014 |
| Electromagnetic environment | IEC 60601-1-2:2000/A1:2014 |
| Quality system | ISO9001 & ISO13485 certified CE marking according to the Council Directive 93/42/EEC |
| Water proof | IPX1 |
| Data review and storage | |
| Data review and storage | 1600- NBP data, 1200 hr trend graph, 120 min full disclosure ECG 1, 200 – alarm & arrhythmia events |
| External interface (standard) | |
| External interface | ECG analog output VGA output Nurse call LAN USB |
| Cardiac Output (optional) | |
| Measurement method | Right heart thermodilution |
| Measurement range | 0.1 l/min – 20.0 l/min |
| Measurement accuracy | ±0.2 l/min or ±10 %, whichever is greater |
| Blood temperature range | 27℃ – 43℃ (80.6℉ – 109.4℉) |
| Blood temperature accuracy | ± 0.1℃ |
| Injection temperature | 0℃ – 27℃ (32℉ – 80.6℉) |
| Brand | VIP |
| Origin | China |
| Quality | High |
| ?system | Solid Gel |
| duration | ? Long time |
The Disposable Microporous PPE Coverall Suit is designed to provide a protective clothing layer in medical, industrial and workplace environments. Its microporous material offers a practical option for disposable protective wear.
Product Highlights:
Product Name: Disposable PPE Coverall Suit
Material: Microporous Fabric
Type: Disposable Protective Clothing
Design: Full-Body Coverall
Category: Personal Protective Equipment (PPE)
Application: Medical & Industrial Environments
| Type | Biochemical Analysis System |
| Brand Name | DIATEK |
| Model Number | DKP-620 |
| Net Weight | 7 kg |
| Gross Weight | 9 kg |
| Instrument Size | 430mm(L)×330mm(W)×140mm(H) |
| Package Dimension | 350mm×450mm×590mm |
| Power Supply | AC 100V~240V, 50/60 Hz |
| Fuses | 2-φ5×20 BGXP1.5A 250V |
| Flow cell | 32 uL quartz flow cell |
| Work environment | Temperature: +5 ~ +40℃;Relative humidity: 20%~80%; |
| Atmospheric pressure:700~1060hpa; | |
| Storage temperature | -20℃ ~ 50℃ |
| Lamp | Tungsten Halogen Lamp, OSRAM 64225 6V/10W |
| Reading range | 0.000~4.500A |
| Warm-up time | 10 min |
| CPU | ARM core CPU |
| Ports | RS232 serial port,parallel printer port,USB port,PS/2 keyboard and mouse port |
| Display | 320×240 LCD |
| Input mode | Touch Screen, Touch pen, external keyboard and mouse |
| Memory Capability | 500 test items and up to 10,000 test data |
| Printer | Built-in Thermal Printer, optional external printer |
| Wavelength Range(nm) | 340,405,510,546,578,630,690(add up to 2 filters in the range of 300~850) |
| Analysis means | end-point, kinetic, fixed-time, nonlinear |
| Carryover | ≤ 1.0% |
| Stability | ≤ 0.01 A |
| Absorbance Accuracy | ≤±0.005A or ±1% |
| Resolution | ±0.001Abs |
| Minimum volume | 200μL ~3000μL |
| Half bandwidth | ≤ 6 nm |
| Fabric | Cotton |
| Gender | Unisex |
| Material | Pure Cotton |
| Color | Blue |
| Category | Doctor General Wear |
| Size | Large |
| Fabric | Cotton |
| Gender | Unisex |
| Material | Pure Cotton |
| Color | Green |
| Category | Doctor General Wear |
| Size | Large |
| Fabric | Cotton |
| Gender | Unisex |
| Material | Pure Cotton |
| Color | Pink |
| Category | Doctor General Wear |
| Size | Large |
NIGHT SPLINT (PLANTAR FASCITIS NIGHT SPLINT)
iMDK C101B1 Fingertip Pulse Oximeter
