| Channel | RANGE | RESOLUTION | CV% |
| pH | 6.00 ~ 9.00 | 0.01 | < 1.0 |
| K+ | 0.50 ~ 10.00 mmol/L | 0.01 | < 1.0 |
| Na+ | 20.0 ~ 200.0 mmol/L | 0.1 | < 1.0 |
| Cl- | 20.0 ~ 200.0 mmol/L | 0.1 | < 1.0 |
| Ca++ | 0.3 ~ 5.0 mmol/L | 0.01 | < 1.5 |
| Li+ | 0.1 ~ 3.0 mmol/L | 0.01 | < 1.5 |
| Ambient Temperature | .5 ℃ ~ 40 ℃ |
| Relative Humidity | ≤ 85% |
| Sun Radiation | Avoid direct sunshine |
| Power Supply | AC100-240V(50/60HZ) |
| Flow Path | Fluid Moving system |
| Reagent pack | Calibration solution in a single reagent pack |
| Calibration | Automatic or On-demand |
| Memory Storage | Up to 1500 patient result, 199 normal QC, 199 Abnormal QC |
| Analyzing Time | 30 seconds after aspiration |
| Sample Volume | Minimum 65µL whole blood or serum |
| Display | Wide LCD(240*128) |
| Input | Keypad (16 alphabets Numeric display, YES or NO) |
| Output | Internal thermal-printer; RS232 |
| Waste Storage | Closed Pack System |
| Reagent Pack | Closed Reagent System |
| DIMENSIONS | 30 x 26 x 36 cm |
| NET WEIGHT | 7.5 kg |
| Cutting mode : Pure: | 350\150W \500 Load\1800V\1200\1.5 Crest Factor. |
| Cutting mode : | Blend1:300\120 W \500 Load\ 2700\2000V\1.9 Crest Factor. |
| Cutting mode : | Blend2: 200\80W \ 500 Load\ 2400\1700V\ 2.3 Crest Factor. |
| Cutting mode : | Blend3:150\60W\ 500 Load\ 2900\3000V\ 3.1 Crest Factor. |
| Coagulation mode : | Point: 100\70W\ 500 Load \ 4.600\3900V\ 4.5 Crest Factor. |
| Coagulation mode : | Soft: 100\70W\ 500 Load\ 3600\3300V\ 6.1 Crest Factor. |
| Bipolar | |
| Coagulation mode : | Standard: 50\50W \ 100 Load \ 600V\ 1.5 Crest Factor. |
| Accessory & Supply Connection | |
| Finger-switch Pencil: | 1 |
| Foot-Switch Pencil: | 2 |
| Patient return electro code: | 1 |
| Footswitch: | 1 |
| AC power supply: | 1 |
| Equipotential bonding: | 1 |
| Power feature | |
| Rate frequency: | 512kHz (110\240v Ac,60\50Hz). |
| Isolated output: YES. | |
| Quantitative display of contact area: | YES, for ”Split” type of neutral electro code. |
| Contact area indicator lamp: | 10 lamps (one for 10% contact), alarm beep and flicker if contact<20%. |
| Split\Solid neutral electrode definition: | YES, ”Split” or ”Solid” indicator lamp lights up. |
| Adjustable alarm volume: | YES |
| Operational duty cycle: | 10 seconds ON, 30 seconds OFF. |
| Cooling method: | Convection |
| Regulation | |
| Type according to EN 60601-1: | CF. |
| Protection class to EN 60601-1: | Class 1. |
| Classification acc. | to MDD 93\42EEC: llb. |
| Physical | |
| Dimension (WxDxH): | 330*450*150mm. |
| Weight: | 7 Kg. |
| Monopolar | |
| Cutting mode : | Pure: 400Watts\ 500 Load (OHMS)\ 2300V\ 1.5 Crest Factor. |
| Cutting mode : | Blend1: 300 Watts\ 500 Load (OHMS)\ 2700V\ 2.1 Crest Factor. |
| Cutting mode : | Blend2: 200Watts\ 500 Load (OHMS)\ 3.200V\ 2.5 Crest Factor. |
| Cutting mode : | Blend3: 150Watts\ 500 Load (OHMS)\ 3.700V\ 3.1 Crest Factor. |
| Coagulation mode : | Point: 120Watts\ 500 Load (OHMS)\ 5.600V\ 6.1 Crest Factor. |
| Coagulation mode : | Soft: 120Watts\ 500 Load (OHMS)\ 3.400V\ 6.1 Crest Factor. |
| Coagulation mode : | Spray: 120Watts\ 500 Load (OHMS)\ 8.500V\ 8.3 Crest Factor. |
| Bipolar | |
| Cutting mode : | Standard: 70Watts\ 200 Load (OHMS)\ 1.450V\ 1.5 Crest Factor. |
| Coagulation mode : | Standard: 70Watts\ 500 Load (OHMS)\ 240V\ 1.5 Crest Factor. |
| Coagulation mode : | Precise: 70Watts\ 200 Load (OHMS)\ 360V\1.5 Crest Factor. |
| Accessory & Supply Connection | |
| Finger-switch Pencil: | 2 |
| Foot-Switch Pencil: | 1 |
| Patient return electro code: | 1 |
| Footswitch: | 1 |
| AC power supply: | 1 |
| Equipotential bonding: | 1 |
| Power feature | |
| Rate frequency: | 512kHz (110\240v Ac,60\50Hz). |
| Isolated output: | YES. |
| Quantitative display of contact area: | YES, for ”Split” type of neutral electro code. |
| Contact area indicator lamp: | 10 lamps (one for 10% contact), alarm beep and flicker if contact<20%. |
| Split\Solid neutral electrode definition: | YES, ”Split” or ”Solid” indicator lamp lights up. |
| Adjustable alarm volume: | YES |
| Operational duty cycle: | 10 seconds ON, 30 seconds OFF. |
| Cooling method: | Convection |
| Regulation | |
| Type according to EN 60601-1: | CF. |
| Protection class to EN 60601-1: | Class 1. |
| Classification acc. | to MDD 93\42EEC: llb. |
| Physical | |
| Dimension (WxDxH): | 460*410*160mm. |
| Weight: | 11.2 Kg. |
Features: Economic Flexible Tip Thermometer
| Type | Multi-function Home Use Fetal Doppler |
| Brand Name | Elite |
| Model Number | FD-643 |
| Instrument classification | Class II |
| System | Two audio output |
| Certificate | CE ISO |
| Display mode | LCD Display |
| Continuous work | over 8 hours |
| Product Name | Oxygen Concentrator |
| Brand | Elite |
| Model | Elite OxyFamily |
| Display | LCD Display |
| Net Weight | 15.9 kg & with wheel |
| Oxygen Flow | 1-5 Litre |
| Function | Nebulization |
| Power Consumption | 320W |
| Alarm | on power failure, high/Low Pressure |
| Product Name | Syringe Pamp |
| Brand | ENMIND |
| Syringe sizes | 5ml, 10ml, 20ml, 30ml, 50/60ml |
| Flow rate accuracy | ±2% |
| Flow rate | 0.1-1500 ml/h |
| VTBI | 0-9999 ml |
| Dose rate units | More than 12 Types |
| Concentration calculate | Automatically |
| Parameters enlarge | Support |
| Purge | Support |
| Titration | Support |
| Bolus setting | Manual bolus, Programmable bolus |
| KVO rate | 0.1-5.0 ml/h |
| Infusion modes | 3 infusion mode |
| Standby mode | Support, standby time 0-23h59m adjustable |
| Drug library | Support, more than 60 |
| Keypad lock | Support |
| Brightness | Adjustable |
| Alarm volume | Adjustable |
| Occlusion levels | 3 levels |
| Anti-bolus | Automatically |
| Records | More than 2000 entries |
| Alarms | VTBl near the end, VTBl infused, Pressure high, Battery nearly empty, Battery empty, No power supply, Reminder alarm, KVO finished |
| Power supply | |
| AC | 11ov-240V, 50/60Hz |
| DC | 12V |
| Battery life | Approx.12 hours (at 5ml/h flow rate with a new fully charged battery) |
| Classification | Class l, CF |
| Waterproof | IP24 |
| Calibration | Automatically |
| Display | 2.8-inch color TFT |
| Input | Keypad |
| Interface | MINI USB |
| Wireless | WIFI ( optional ) |
| Weight | Approx. 1 .7 kg |
EN-S7 Smart Syringe Pump is a very popular and high-quality medical product using all over the world by experts in hospital and diagnostics
| Brand | ENMIND |
| Alarm Volume | Adjustable |
| Brightness | Adjustable |
| Screen | 4.3-inch color touch screen |
| Screen Lock | Avoid misoperation |
| Purge | Remove the air bubble |
| History Record | More than 5000 entries |
| Standby Mode | Standby time 00-99h59m adjustable |
| DPS | Real-time pressure display in graphically and numerically |
| DPS | Real-time pressure display in graphically and numerically |
| AC Power | 110V-240V, 50/60Hz |
| External DC Power | 12V Lithium Polymer battery ll.lV 2600mAh |
| Brand | ENMIND |
| Operation System | Smart |
| Modes | 7 infusion modes |
| Rate range | 0.01ml/h- 1200ml/h (increments 0.01ml/h) |
| Micro mode | 100ml/h to 1200ml/h |
| VTBI | 0.01-9999ml – 0.01 steps |
| Battery Life | 9h battery life |
| Dimensions | 235(l)x 95(w) x 129(h)mm |
| Design | Stackable |
| Product Name | Hematology Analyzer |
| Brand | Erba |
| Model | Elite-3 |
| Sample method | An open tube system with automatic sample rotor |
| Sample volume | 25 μl of whole blood, pre-diluted mode |
| Throughput | 80 tests/hour |
| Results | within 45 seconds |
| Storage capacity | 10 000 results, with RBC, PLT, and WBC 3-Part histogram |
| Product Name | Elisa Reader |
| Brand | Erba |
| System type | Open System |
| Plate types | 96 well plates |
| Wells type | Flat, U and V wells |
| Operating modes | Absorbance, Quantitative, Qualitative, Semi-quantitative, Kinetic modes |
| Measurement modes | Continuous / Step |
| Shaking modes | Three linear speeds-Low, medium and fast |
| Wavelength Selection | Monochromatic, Bi-chromatic, multi-chromatic |
| Calculation modes | Non-linear standard, Cut-off, Index Formula, Column subtraction, Linear regression, Point to Point, Cubic spline, Linear-Log |
| Number of programmable standards/calibrators | Up to 10 standards storage/display/printing of multi-standard curves and cut off equations for all parameters |
| Test Programs | 100 totally “open” test programs |
| Photometer | The optical system, 8 measurement channels, Standard four filters 405nm,450nm,492nm,630nm (optional two filters 578nm, 700nm), Light source – 13.8V/50W Quartz |
| Halogen lamp | Wavelength range – 400 to 800 nm |
| Measurement range – 400 to 800 nm (0 to 3.5 OD) | |
| Measurement time | NORMAL – 16 seconds single wavelength |
| Display | High resolution graphics LCD 320 * 240 pixels |
| Keyboard | Rugged waterproof & membrane panel |
| PC communication | Serial RS232 & USB 2.0 |
| Built-in thermal printer | High resolution, 384 dots per line, thermal type with full graphics facility, and options for connecting External parallel printer |
| Computer interfacing software | Windows-based software ELi-LMS with data management (optional), PC link identification software, TNW enables reading MIKROLATEST Kits |
| Reports on internal and external printers | Alphanumeric patient ID-based linear and matrix reports with OD, Conc, Cut off interpretation, etc, Calibration graphs printed. Reports generated for the last 480 sample”s is view/printed/stored, Lab name |
| Online help | At each step online help in each menu. Beeps and online instructions on erroneous entry. Special HELP key on the keyboard. |
| Operating temperature | 20 to 40-degree celsius |
| Storage temperature | 10 to 50-degree celsius |
| Humidity | Max 80% RH, non-condensing |
| Power supply | 18V DC using external auto-ranging, SMPS adapter, 115/230 VAC +- 10% 50/60 Hz Max, 100 Watt. |
| Diamension | 502 * 369 * 216 mm |
| Weight | 7 Kg |
| Measuring principle | Infrared sensor |
| Measuring time | 30 minutes |
| Measuring precision | <0.2 mm |
| Reproducibility | < 3% |
| Temperature Precision | <0.3?C |
| Sample volume | <1.6mL whole blood anticoagulant |
| Reading channel | 10 |
| Display | LCD |
| Interface | RS-232 serial port |
| Internal thermal printer | |
| Operation conditions | 15C?~32?C , Humidity ?85% |
| Power supply | AC 220V/110V ?10%, 50/60 Hz |
| Dimension | 320mm?260mm?158mm (L?W?H) |
| Net weight | ? ?? 5.0 kg |
| Cap Color | Additives | ?Material | Volume/Tube size |
| Black | Sodium Citrate 3.2% (ESR Tube ) | Glass (vacuum) | 1.28ml, 8?120mm |
| Measuring principle | Infrared sensor |
| Measuring time | 30 minutes |
| Measuring precision | <0.2 mm |
| Reproducibility | < 3% |
| Temperature Precision | <0.3?C |
| Sample volume | <1.6mL whole blood anticoagulant |
| Reading channel | 10 |
| Display | LCD |
| Interface | RS-232 serial port |
| Internal thermal printer | |
| Operation conditions | 15C?~32? C, Humidity ?85% |
| Power supply | AC 220V/110V ?10%, 50/60 Hz |
| Dimension | 320mm?260mm?158mm (L?W?H) |
| Net weight | 5.0 kg |
| Cap Color | Additives | ?Material | Volume/Tube size |
| Black | Sodium Citrate 3.2% (ESR Tube ) | Glass (vacuum) | 1.28ml, 8?120mm |
| Application area | Erythrocyte sedimentation rate analysis |
| Measuring principle | Infrared sensor |
| Reading channels | 30 available channels |
| Loading capability | Up to 30 samples at a time |
| Loading pattern | Random |
| Measuring time | 30 minutes or 60 minutes selectable |
| Throughput | Up to 60 samples per hour |
| Analysis result | In Westergren ESR value (mm/hr) |
| Temperature compensation | Refer to 18?C automatically (selectable) |
| Reading resolution | 0.2mm |
| Reproducibility | < 0.3% or 2mm/1h |
| Result resolution | 1mm/1h |
| Blood level range | 50mm~64mm |
| Display | LCD |
| Input | Touch screen |
| Interface | RS-232 serial port |
| Internal thermal printer | |
| Power supply | AC 220V/110V ?10%, 50/60/Hz, 50W |
| Operation conditions | 15C?~32?C Humidity ?85% |
| Dimension | 400mm?300mm?200mm(L?W?H) |
| Net weight | 11.5kg |
| Cap Color | Additives | ?Material | Volume/Tube size |
| Black | Sodium Citrate 3.2% (ESR Tube ) | Glass (vacuum) | 1.28ml, 8?120mm |
| Product Name | Urine Analyzer |
| Brand | VES-Matic |
| Model | VES-Matic-20 |
| Operation Mode | Fully Automatic |
| Sample Mode | Whole Blood |
| Sample Volume | 1.2 ml |
| Storage | 40000 Samples |
| Operating Voltage | 90-265 V |
| Power Supply | 65 W |
| Printer | Alphanumeric Printer |
| Operational Ambient Temperature | 15 to 35 Degree C |
| User Interface | RS 232C |
| Analysis Method | Kinetics |
| Product Name | Portable ventilator |
| Brand | ETERNITY |
| Model | SH-210 |
| Patient type | Adult & Pediatric |
| Driven mode | Gas driven electronically controlled |
| Working mode | pressure limited, time cycled, volume controlled |
| Setting | Electronic Knob |
| Ventilation mode | VCV, SIGH, SIMV+VCV, CPAP, SPONT |
| Waveform | P-T, F-T, V-T, P-V Loop, V-F Loop |
| Tidal volume | 0~1500ml |
| Breathing rate | 4~100bpm |
| I:E | 3:1~1:5 |
| Trigger sensitivity | -2KPa~PEEP |
| PEEP | 0~2KPa |
| Oxygen | 50~100% |