Explore Erba Microplate ELISA and Microbiology Readers at Timely Product Ltd for laboratory testing applications. These instruments support different types of laboratory analysis depending on the model, measurement technology, and compatible testing methods. Whether you are equipping a diagnostic laboratory or upgrading existing equipment, check each model's specifications to find a suitable option for your requirements.
| Product Name | Elisa Reader |
| Brand | Erba |
| System type | Open System |
| Plate types | 96 well plates |
| Wells type | Flat, U and V wells |
| Operating modes | Absorbance, Quantitative, Qualitative, Semi-quantitative, Kinetic modes |
| Measurement modes | Continuous / Step |
| Shaking modes | Three linear speeds-Low, medium and fast |
| Wavelength Selection | Monochromatic, Bi-chromatic, multi-chromatic |
| Calculation modes | Non-linear standard, Cut-off, Index Formula, Column subtraction, Linear regression, Point to Point, Cubic spline, Linear-Log |
| Number of programmable standards/calibrators | Up to 10 standards storage/display/printing of multi-standard curves and cut off equations for all parameters |
| Test Programs | 100 totally “open” test programs |
| Photometer | The optical system, 8 measurement channels, Standard four filters 405nm,450nm,492nm,630nm (optional two filters 578nm, 700nm), Light source – 13.8V/50W Quartz |
| Halogen lamp | Wavelength range – 400 to 800 nm |
| Measurement range – 400 to 800 nm (0 to 3.5 OD) | |
| Measurement time | NORMAL – 16 seconds single wavelength |
| Display | High resolution graphics LCD 320 * 240 pixels |
| Keyboard | Rugged waterproof & membrane panel |
| PC communication | Serial RS232 & USB 2.0 |
| Built-in thermal printer | High resolution, 384 dots per line, thermal type with full graphics facility, and options for connecting External parallel printer |
| Computer interfacing software | Windows-based software ELi-LMS with data management (optional), PC link identification software, TNW enables reading MIKROLATEST Kits |
| Reports on internal and external printers | Alphanumeric patient ID-based linear and matrix reports with OD, Conc, Cut off interpretation, etc, Calibration graphs printed. Reports generated for the last 480 sample”s is view/printed/stored, Lab name |
| Online help | At each step online help in each menu. Beeps and online instructions on erroneous entry. Special HELP key on the keyboard. |
| Operating temperature | 20 to 40-degree celsius |
| Storage temperature | 10 to 50-degree celsius |
| Humidity | Max 80% RH, non-condensing |
| Power supply | 18V DC using external auto-ranging, SMPS adapter, 115/230 VAC +- 10% 50/60 Hz Max, 100 Watt. |
| Diamension | 502 * 369 * 216 mm |
| Weight | 7 Kg |
| Measuring principle | Infrared sensor |
| Measuring time | 30 minutes |
| Measuring precision | <0.2 mm |
| Reproducibility | < 3% |
| Temperature Precision | <0.3?C |
| Sample volume | <1.6mL whole blood anticoagulant |
| Reading channel | 10 |
| Display | LCD |
| Interface | RS-232 serial port |
| Internal thermal printer | |
| Operation conditions | 15C?~32?C , Humidity ?85% |
| Power supply | AC 220V/110V ?10%, 50/60 Hz |
| Dimension | 320mm?260mm?158mm (L?W?H) |
| Net weight | ? ?? 5.0 kg |
| Cap Color | Additives | ?Material | Volume/Tube size |
| Black | Sodium Citrate 3.2% (ESR Tube ) | Glass (vacuum) | 1.28ml, 8?120mm |
| Measuring principle | Infrared sensor |
| Measuring time | 30 minutes |
| Measuring precision | <0.2 mm |
| Reproducibility | < 3% |
| Temperature Precision | <0.3?C |
| Sample volume | <1.6mL whole blood anticoagulant |
| Reading channel | 10 |
| Display | LCD |
| Interface | RS-232 serial port |
| Internal thermal printer | |
| Operation conditions | 15C?~32? C, Humidity ?85% |
| Power supply | AC 220V/110V ?10%, 50/60 Hz |
| Dimension | 320mm?260mm?158mm (L?W?H) |
| Net weight | 5.0 kg |
| Cap Color | Additives | ?Material | Volume/Tube size |
| Black | Sodium Citrate 3.2% (ESR Tube ) | Glass (vacuum) | 1.28ml, 8?120mm |
| Application area | Erythrocyte sedimentation rate analysis |
| Measuring principle | Infrared sensor |
| Reading channels | 30 available channels |
| Loading capability | Up to 30 samples at a time |
| Loading pattern | Random |
| Measuring time | 30 minutes or 60 minutes selectable |
| Throughput | Up to 60 samples per hour |
| Analysis result | In Westergren ESR value (mm/hr) |
| Temperature compensation | Refer to 18?C automatically (selectable) |
| Reading resolution | 0.2mm |
| Reproducibility | < 0.3% or 2mm/1h |
| Result resolution | 1mm/1h |
| Blood level range | 50mm~64mm |
| Display | LCD |
| Input | Touch screen |
| Interface | RS-232 serial port |
| Internal thermal printer | |
| Power supply | AC 220V/110V ?10%, 50/60/Hz, 50W |
| Operation conditions | 15C?~32?C Humidity ?85% |
| Dimension | 400mm?300mm?200mm(L?W?H) |
| Net weight | 11.5kg |
| Cap Color | Additives | ?Material | Volume/Tube size |
| Black | Sodium Citrate 3.2% (ESR Tube ) | Glass (vacuum) | 1.28ml, 8?120mm |
The ESR Analyzer Ves-Matic-20 is a laboratory instrument for erythrocyte sedimentation rate (ESR) testing. It may be considered by diagnostic laboratories looking to incorporate ESR measurement into their routine testing workflow. Before purchasing, confirm the model's measurement method, sample requirements, testing capacity, and compatibility with your laboratory procedures.
| Product Name | Urine Analyzer |
| Brand | VES-Matic |
| Model | VES-Matic-20 |
| Operation Mode | Fully Automatic |
| Sample Mode | Whole Blood |
| Sample Volume | 1.2 ml |
| Storage | 40000 Samples |
| Operating Voltage | 90-265 V |
| Power Supply | 65 W |
| Printer | Alphanumeric Printer |
| Operational Ambient Temperature | 15 to 35 Degree C |
| User Interface | RS 232C |
| Analysis Method | Kinetics |
| Product Name | Portable ventilator |
| Brand | ETERNITY |
| Model | SH-210 |
| Patient type | Adult & Pediatric |
| Driven mode | Gas driven electronically controlled |
| Working mode | pressure limited, time cycled, volume controlled |
| Setting | Electronic Knob |
| Ventilation mode | VCV, SIGH, SIMV+VCV, CPAP, SPONT |
| Waveform | P-T, F-T, V-T, P-V Loop, V-F Loop |
| Tidal volume | 0~1500ml |
| Breathing rate | 4~100bpm |
| I:E | 3:1~1:5 |
| Trigger sensitivity | -2KPa~PEEP |
| PEEP | 0~2KPa |
| Oxygen | 50~100% |
| Product Name | RMS Vega 201 Treadmill Test (TMT) |
| Model | VEGA 201 |
| Display Type | Digital |
| Grade | Semi-Automatic |
| Brand | RMS |
| Supply | AC |
| Minimum Order Quantity | 1 Unit |
| SIZE |
|---|
| UNIVERSAL |
| SIZE |
|---|
| UNIVERSAL |
| Product designation | Facial brush |
| Attachments | 4 |
| Operating mode (mains/rechargeable battery/battery) | Battery-powered |
| Operation light | yes |
| Operating time | 30 minutes |
| Function | Rotation circular and oscillating |
| Charging time | 6 hours |
| Output in watts | 5 |
| Output levels | 3 |
| Timer | yes |
| Water-resistant | yes |
| Product dimensions (L x W x H) | 18.5 x 4 x 4 cm (without attachment) |
| CE | yes |
| Ultrasound frequency | 2.5 MHz Continuous Wave |
| Acoustic Output | Low Power – exemption |
| Audio bandwidth and power | 1.25-250 Hz, 100 mW(32Ω stereo headset) |
| Fetal Heart Rate | Display: 3 digit FHR |
| Range | 50-240 bpm |
| Accuracy | ±1% or ±1 bpm whichever is greater |
| Resolution | 1 bpm |
| Power Supply | 3 x AAA 1.5V Alkaline |
| Auto Shut off | About 2 mins no signal |
| Unit Controls | Buttons: On/Off, Volume |
| Operating temperature | 5 – 40°C |
| Operating humidity | 30 – 80% |
| Dimension | 296 (W) x 305.5 (H) x 92.5 (D) mm, approx. 2.9 kg |
| Display | 7-segment LED 2 channels (HR, UC) |
| Printer | Thermal array type Print speed: 1, 2, 3 cm/min Paper feeding function |
| Power | Input: AC100 – 240v (50/60 Hz) Output: DC18v, 2.5A Consumption: 80w |
| External Link | RS-232C: Program download Central (option) |
| Fetal Heart Rate | Input Signal: Ultrasound pulsed doppler Ultrasound frequency: 1.0 MHz Intensity: FHR range: 50~240 BPM FHR accuracy: 120~160: ±1 BPM |
| Uterine Contraction | External type Frequency response: DC ~0.5Hz Reference(zero) control Measurement range: 0~99 units |
| Fetal Movement Measurement | Detection source: Ultrasound pulsed doppler |
| Indicators | Heart rhythm with signal quality Alarm, printing on/off state AC power |
| Sound | Doppler sound Alarms sound Information sound |
| Setup | Alarm upper/low limit value Record speed, apper grid, fetal movement on/off, time/date, print contrast, auto print period |
| Function | Event mark function Auto fetal movement detection |
| Standard Accessories | Ultrasound doppler probe – 1 ea UC probe – 1 ea Event marker jack – 1 ea Printer paper – 2 rolls Power adaptor & cord – 1 ea Ultrasound gel – 1 ea Probe belt – 2 ea Operation manual – 1 ea Stand – 1 ea Basket – 1 ea Bag – Optional |
| SIZE | INCHES | CM |
|---|---|---|
| Small | Below 2 | Below 5 |
| Medium | 2-3 | 5-7.5 |
| Large | 3-4 | 7.5-10 |
| SIZE | INCHES | CM |
|---|---|---|
| Small | Below 2 | Below 5 |
| Medium | 2-3 | 5-7.5 |
| Large | 3-4 | 7.5-10 |
| SIZE |
|---|
| UNIVERSAL |
| SIZE | INCHES | CM |
|---|---|---|
| Small | Below 2 | Below 5 |
| Medium | 2-3 | 5-7.5 |
| Large | 3-4 | 7.5-10 |
Baby Food Warmer BY 52 Beurer (Germany)