Brand | Bionet |
Model | BM 5 |
Condition | New |
Warranty | 12 month(s) |
Origin | Russia |
Category | Patient Monitor |
Pulse Rate Range | 0-300 bpm |
Display | 10.4 inch |
Brand | Bionet |
Frequency | 50-60 Hz |
Resolution | 800×600 Pixel |
Dimensions | 270x250x184.5 mm |
Brand | Curative |
Model | Cavent |
Measured parameter | TEMP, ECG, RESP, NIBP, IBP, SpO2 |
Applications | Intensive care |
Configuration | Portable |
Patient type | Pediatric |
Screen size | 12 in |
ECG | Heart rate display range | 15bpm ~ 350bpm |
Heart rate display accuracy | ± 1% or ± 2bpm, whichever is greater | |
Sweeping speed | 12.5mm/s, 25mm/s, 50mm/s | |
Sensitivity selection | 1/2, 5mm/mV ×1, 10mm/mV ×2, 20mm/mV | |
CMRR | ≥ 89dB | |
RESP | Measuring range | 0rpm~120rpm |
Accuracy | ±5% or ±2 rpm | |
Alarm limits setting range | 0rpm~120rpm | |
TEMP | Measuring range | 25.0℃ ~45.0℃ |
Measuring accuracy | ±0.2℃ | |
Responding time | ≤150s | |
NIBP | Measuring method | Oscillometric Technique |
Measuring range | 0 mmHg~300mmHg | |
Accuracy | Maximal mean difference | ±5 mmHg |
Maximal standard deviation | 8 mmHg | |
Measurement range | Adult | SYS 40 ~ 255 mmHg |
MAP 20 ~ 215 mmHg | ||
DIA 10 ~ 195 mmHg | ||
Pediatric patient | SYS 40 ~ 200 mmHg | |
MAP 20 ~ 165 mmHg | ||
DIA 10 ~ 150 mmHg | ||
Neonate | SYS 40 ~ 135 mmHg | |
MAP 20 ~ 110 mmHg | ||
DIA 10 ~ 95 mmHg | ||
SpO2 | Measuring range | 35%~100% |
Low perfusion capability | 0.4%~5% | |
Accuracy | Not greater than 3% for SpO2 range from 70% to 100% | |
PR | Measuring range | 30bpm~240bpm |
Measuring accuracy | ±2bpm or ±2%, whichever |
ECG | Lead mode: 3-lead or 5-lead Lead selection: I, II, III, aVR, aVL, aVF, V Waveform: 5-lead, 2-lead, 1-lead Gain: 2,5mm / mV, 5,0mm / mV, 10mm / mV, 20mm / mV, 40mm / mV Scanning speed: 12,5mm / s, 25mm / s, 50mm / s |
HR: | Measurement and alarm range: 15~350bpm Precision: ±1% or ±1bpm, whichever is higher alarm accuracy: ± 2bpm Resolution: 1bpm ST-segment monitoring: measurement and alarm range: -2.0mV~+2.0mV Precision: -0.8mv~+0.8mv ±0.04mv or ±10%, whichever is higher Other range: unspecified arrhythmic analysis: ASYSTOLE, VFIB / VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACH |
RESPIRATION | Method: R-F(RA-LL) Respiration rate: measurement and alarm range: 0~150rpm Resolution: 1 rpm Respiration accuracy: ±2 rpm Alarm accuracy: ±3 rpm Apnea alarm: 10~40s Scanning speed: 6.25 mm / s, 12.5 mm / s, 25 mm / s. |
NIBP | Method: Oscillometry Mode: Manual / AUTO / Continuous Measurement period in AUTO mode: 1/2/3/4/5/10/15/60/90/120/240/480/960 minutes Continuous mode measurement interval: 5 minutes Measurement and warning range: 10 ~ 270 mmHg Resolution: 1 mmHg Cuff stress accuracy: ±3 mmHg Measurement accuracy: maximum mean deviation: ±5 mmHg Maximum standard deviation: 8 mmHg Over-pressure protection: adult mode |
SpO2 | Measurement and warning range: 0 ~ 100 percent resolution: 1 percent accuracy of measurement: 70 percent ~100 percent: ±2 percent; 0 percent ~69 percent: unspecified. |
PR | Measuring and alarm range: 30 ~ 250 bpm Measuring accuracy: ±2 bpm or ±2%, whichever is higher |
TEMP | Channel: dual-channel Measurement and alarm range: 0 ~ 50ºC Resolution: 0.1 ºC Accuracy: ±0.1 ºC |
EtCO2 | Method: Sidestream or Mainstream CO2 measurement range: 0~150mmHg CO2 resolution: 0~69mmHg: 0.1mmHg 70~150mmHg CO2 accuracy: 0.25mmHg CO2 accuracy: 0~40mmHg: ±2mmHg 41~70mmHg: ±5 percent 71~100mmHg: ±8 percent 101~150mmHg CO2 accuracy: ±10 percent AwRR accuracy: ±1 rpm Apnea alarm: yes. |
IBP | Channel: dual-channel label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measurement and warning range: -10~300 mmHg Resolution: 1 mmHg Precision: ±2% or 1 mmHg, whichever is higher Power supply: AC 100-240V, 50/60Hz Safety classification: Class I, CF defibrillation-proof component added. |
ECG | Lead mode: 3-lead or 5-lead Lead selection: I, II, III, aVR, aVL, aVF, V Waveform: 5-lead, 2-lead, 1-lead Gain: 2,5mm / mV, 5,0mm / mV, 10mm / mV, 20mm / mV, 40mm / mV Scanning speed: 12,5mm / s, 25mm / s, 50mm / s |
HR: | Measurement and alarm range: 15~350bpm Precision: ±1% or ±1bpm, whichever is higher alarm accuracy: ± 2bpm Resolution: 1bpm ST-segment monitoring: measurement and alarm range: -2.0mV~+2.0mV Precision: -0.8mv~+0.8mv ±0.04mv or ±10%, whichever is higher Other range: unspecified arrhythmic analysis: ASYSTOLE, VFIB / VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACH |
RESPIRATION | Method: R-F(RA-LL) Respiration rate: measurement and alarm range: 0~150rpm Resolution: 1 rpm Respiration accuracy: ±2 rpm Alarm accuracy: ±3 rpm Apnea alarm: 10~40s Scanning speed: 6.25 mm / s, 12.5 mm / s, 25 mm / s. |
NIBP | Method: Oscillometry Mode: Manual / AUTO / Continuous Measurement period in AUTO mode: 1/2/3/4/5/10/15/60/90/120/240/480/960 minutes Continuous mode measurement interval: 5 minutes Measurement and warning range: 10 ~ 270 mmHg Resolution: 1 mmHg Cuff stress accuracy: ±3 mmHg Measurement accuracy: maximum mean deviation: ±5 mmHg Maximum standard deviation: 8 mmHg Over-pressure protection: adult mode |
SpO2 | Measurement and warning range: 0 ~ 100 percent resolution: 1 percent accuracy of measurement: 70 percent ~100 percent: ±2 percent; 0 percent ~69 percent: unspecified. |
PR | Measuring and alarm range: 30 ~ 250 bpm Measuring accuracy: ±2 bpm or ±2%, whichever is higher |
TEMP | Channel: dual-channel Measurement and alarm range: 0 ~ 50ºC Resolution: 0.1 ºC Accuracy: ±0.1 ºC |
EtCO2 | Method: Sidestream or Mainstream CO2 measurement range: 0~150mmHg CO2 resolution: 0~69mmHg: 0.1mmHg 70~150mmHg CO2 accuracy: 0.25mmHg CO2 accuracy: 0~40mmHg: ±2mmHg 41~70mmHg: ±5 percent 71~100mmHg: ±8 percent 101~150mmHg CO2 accuracy: ±10 percent AwRR accuracy: ±1 rpm Apnea alarm: yes. |
IBP | Channel: dual-channel label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measurement and warning range: -10~300 mmHg Resolution: 1 mmHg Precision: ±2% or 1 mmHg, whichever is higher Power supply: AC 100-240V, 50/60Hz Safety classification: Class I, CF defibrillation-proof component added. |
Specifications | |
ECG | |
Lead type | 3-lead or 5-lead selectable |
Lead selection, 3-lead | I, II, III |
Lead selection, 5-lead | I, II, III, aVR, aVL, aVF, V |
HR measurement | Adult / pediatric: 15 bpm – 300 bpm Neonatal: 15 bpm – 300 bpm Step: 1 bpm |
HR accuracy | ±5 bpm or ±1 %, whichever is greater |
Arrhythmia | 21 calls |
ST measurement range | -2.5 mV – +2.5 mV |
Waveform speed | 6.25 mm/s,12.5 mm/s, 25 mm/s, 50 mm/s |
Gain selection | x 1/4, x 1/2, x 1, x 2, x 4, Auto |
Pacemaker detection | Yes |
Protection | Against electrosurgical interference and defibrillation |
Non-invasive blood pressure (NBP) | |
Method | Automatic oscillometric |
Parameters | SYS/DIA/MAP/Pulse Rate |
Operating mode | Manual/Auto/STAT |
Auto measure intervals | 3, 5, 10, 15, 30, 60, 90, 120, 240, 480 minutes |
Units | mmHg/kPa |
Cuff pressure range, adult / pediatric | 0 – 300 mmHg ( 0 kPa – 40.0 kPa) |
Cuff pressure range, neonate | 0 – 150 mmHg ( 0 kPa – 20.0 kPa) |
Systolic measurement range, adult/ pediatric | 30 mmHg – 254 mmHg (4.0 kPa – 33.9 kPa) |
Systolic measurement range, neonate | 30 mmHg – 135 mmHg (4.0 kPa – 18.0 kPa) |
Diastolic measurement range, adult / pediatric | 10 mmHg – 220 mmHg (1.3 kPa – 29.3 kPa) |
Diastolic measurement range, neonate | 10 mmHg – 110 mmHg (1.3 kPa – 14.7 kPa) |
MAP measurement range, adult / pediatric | 20 mmHg – 235 mmHg (2.7 kPa – 31.3 kPa) |
MAP measurement range, neonate | 20 mmHg – 125mmHg (2.7 kPa – 16.7kPa) |
Accuracy, maximum standard deviation | 8 mmHg (1.1 kPa) |
Accuracy, mean error | ±5 mmHg (±0.7 kPa) |
Pulse rate range | 40 bpm – 240 bpm |
Pulse rate accuracy | ±5bpm or ±5%, whichever is greater |
SpO2 (Philips SpO2 technology) | |
Measurement range | 0 – 100 % |
Accuracy | 70 % – 100 %, depends on sensor; 0 – 69 %, unspecified |
Waveform speed | 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s |
Pulse rate range | 30 bpm – 300 bpm |
Pulse rate accuracy | ±2 bpm or ±2%, whichever is greater |
Perfusion index | Yes |
Respiration (RESP) | |
Measurement method | Thoracic impedance |
Measurement range | 0 rpm – 150 rpm |
Accuracy | 0rpm – 120rpm: ±1 rpm; 121rpm – 150rpm: ±2 rpm |
Waveform speed | 6.25 mm/s,12.5 mm/s, 25 mm/s, 50 mm/s Accuracy undefined |
Gain selection | x 1/2, x 1, x 2 |
Apnea alarm | Yes, 10 – 60 s |
Work mode | Auto or manual (threshold) |
RESP lead | RA-LL |
Temperature (TEMP, 2-channel) | |
Measurement range | 0 – 50℃ (32℉ – 122℉) |
Resolution | 0.1℃ (0.2℉) |
Accuracy | ±0.1℃ (±0.2℉) (without sensor) |
Units | ℃ / ℉ |
Minimum measuring time | Attachable skin surface probe: less than 10 minutes Esophageal/rectal probe: less than 2 minutes |
Capnopgraphy (etCO2, optional) | |
Method | Microstream, infrared absorption (Oridion) |
Parameters | awRR, etCO₂, inCO₂ |
Measurement range | 0 – 99 mmHg (0 kPa – 13.2 kPa) |
Accuracy+C781, 0 – 38 mmHg (0 kPa – 5.1 kPa) | ±2 mmHg (±0.28 kPa) |
Accuracy, 39 mmHg – 99 mmHg (5.2 kPa – 13.2 kPa) | ± (5% of reading + 0.08% for every 1 mmHg (0.13 kPa) above 38 mmHg (5.1kPa) |
awRR range | 0-150 rpm |
awRR accuracy, 3 rpm – 70 rpm | ±1 rpm |
awRR accuracy, 71 rpm – 120 rpm | ±2 rpm |
awRR accuracy, 121 rpm – 150 rpm | ±3 rpm |
Invasive Blood Pressure | |
Accuracy | ±4 mmHg (0.53 kPa) or ±4 % of reading, whichever is greater |
Invasive blood pressure (IBP, 2-channel, optional) | |
Parameters | SYS/DIA/MAP/Pulse Rate |
Measurement range | -50 – 400 mmHg (-6.6 kPa – 53.3 kPa) |
Waveform speed | 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s |
Resolution | 1 mmHg (0.13 kPa) |
Units | mmHg/kPa/cmH₂O |
Transducer sensitivity | 5 uV/V/mmHg |
Pulse rate range | 30 bpm – 254 bpm |
Pulse rate accuracy | ±2bpm or ±2%, whichever is greater |
Sampling rate | 62.5 samples per second |
Recorder (optional) | |
Type | Built-in thermal recorder, 3 channels |
Print mode | Real-time recording, timed recording, alarm-activated recording |
Print speed | Auto, 12.5 mm/s, 25 mm/s, 50 mm/s |
Display | |
Type | Color TFT LCD, 4:3 |
Size | 10.4+611:631″ |
Resolution | 800 x 600 pixels |
Channels | Max 11 channels (auto waveform channel height adjustment) |
Power supply | |
AC power input | 100 – 240 VAC, 50/60 Hz |
Battery | Rechargeable Li-Ion battery Maximum 2.5 hour continuous monitoring (1 battery) |
Weight and dimensions | |
Net weight | Approx. 3.5 kg without battery |
Dimensions (w x d x h) | 316 mm x 265 mm x 131 mm (12.5 in. x 10.5 in. x 5.2 in.) |
Safety approval and quality system | |
Safety standard | IEC 60601-1-2:2014 |
Electromagnetic environment | IEC 60601-1-2:2000/A1:2014 |
Quality system | ISO9001 & ISO13485 certified CE marking according to the Council Directive 93/42/EEC |
Water proof | IPX1 |
Data review and storage | |
Data review and storage | 1600- NBP data, 1200 hr trend graph, 120 min full disclosure ECG 1, 200 – alarm & arrhythmia events |
External interface (standard) | |
External interface | ECG analog output VGA output Nurse call LAN USB |
Cardiac Output (optional) | |
Measurement method | Right heart thermodilution |
Measurement range | 0.1 l/min – 20.0 l/min |
Measurement accuracy | ±0.2 l/min or ±10 %, whichever is greater |
Blood temperature range | 27℃ – 43℃ (80.6℉ – 109.4℉) |
Blood temperature accuracy | ± 0.1℃ |
Injection temperature | 0℃ – 27℃ (32℉ – 80.6℉) |
Brand | YK-8000B |
Display | 12.1-inch high-resolution color TET LCD |
Alarms | 3-level audio/visual |
Working Capability | 2-hour |
Battery | Built-in rechargeable lithium battery |
Size | 12 * 11.4 * 6.4 inch |
Weight | 8.8 lb |
Electrical Specification | 100-240v AC, 50/60Hz, Max Input Power: 70VA |
Battery | 11.1V 2200mAh rechargeable lithium battery |
Standard configuration | SpO2, PR, NIBP, ECG, RESP, TEMP |
Optional Configuration | Nellcor SpO2, 2-IBP, ETCO2, Touch screen, Built-in Thermal Printer |
Various interfaces | standard screen, trend screen, oxy CRG screen, NIBP list screen, big front screen. |
IBP | Method: Oscillometry |
Modes: Manual/Auto/ Comtinuous | |
Auto measure time: Adjustable | |
Measurement range:10-270mmHg | |
ECG | Lead mode: 3-lead or 5-lead |
Lead selection: I;II;III,avR;avF;V | |
Heart rate range: Adult:15-300bpm;Pediatric/Neonatal:15-300bpm | |
ECG waveform: 2 channels | |
Accuracy: ±1 bpm or ±1%,which is greater | |
S-T segment detection; measurement range: 2.0mv~2.0mv | |
Alarm: Yes, audible and visual alarm, alarm events review | |
SPO2 | Measurement range:0-100% |
Accuracy:70-100%,±2%,0-69%,upspecified | |
Auto measure time: Adjustable | |
Pulse Rate | Range:20-254bpm |
Accuracy: ±3bpm | |
Respiration | Method: RA-LL impedance |
Range: Adult:0-120rpm;pediatric/neonatal:0-150rpm | |
Apnca alarm: Yes | |
Temperature | Range:0-500 |
Accuracy: ± 0.10 | |
Channel: Dual-channel |
Display: | 10.4 Inch Multi-Parameter Color Patient |
Monitor: | 2ch ECG, SpO2, NIBP, 2ch IBP, 2ch Temp, Respiration, Optional Built-in EtCO2 |
Built-In EtCO2 Module: | Built-In EtCO2 Mode (EtCO2 module is inside of monitor Respironics sidestream module |
Easy to use: | Selectable 5 waveform / 4 waveform / 3 waveform Display/Enabled / disabled /parameters, the color, and font of each parameter are changeable changeable |
ECG Analysis: | 12 kinds of arrhythmia analysis ST Level & PVC count real-time display |
IBP: | ABP / CVP / PAP / LAP |
Multi-national Software: | English, French, German, Spanish, Italian, Portuguese |
Transportable: | Up to 4 hours use with battery Less than 3 kg of lightweight |
Quick start-up: | Less than 2 seconds |
Trend data: | 72 hours of graphics and tabular trend Interface RS-232 port and LAN port |
Frequency Response | 0.5~40Hz |
Sweep Speed(mm/sec) | 12.5, 25, 50 |
Heart Rate Range | 0~350bpm |
Heart Rate Accuracy | ±1% |
Respiration Rate Measurement Range | : 0~120bpm |
Respiration Rate Accuracy | ±1bpm or 5%(choice max) |
Respiration Rate Resolution | 1bpm |
CO2 Measurement Range | 0~10.0% |
CO2 Accuracy | ±2mmHg or 5%(choice max) |
CO2 Response Time | 180ms |
Frequency response | Monitor: 0.5~40 Hz |
Heart rate range | 0-350 BPM |
Heart rate accuracy | ± 1 % |
ST segment deviation analysis | -0.8~+0.8mV |
ST accuracy | ±0.02mv |
SPO2 measurement range | 0 – 100 % |
Accuracy | ±2% at 70~100% |
Temperature | 5~40 ℃ -20~70 ℃ |
Relative humidity | ≤ 80% ≤ 95% |
Input | 98-260 V AC, 50/60Hz |
Consumption | ≤ 80VA |
Brand Name | Chenwei |
Model Number | Beta 12 |
Place of Origin | Guangdong, China |
Product name | 15inch patient monitor |
Standard | ECG, SPO2, NIBP, Temp, Resp., HR |
Optional | EtCO2, 2IBP, Massimo SPO2, Printer, etc. |
Display | 12.1 inch TFT screen |
Optional Accessories | Aluminum trolley, wall mount stand |
Size | 300*170*305 mm |
Warranty | 1 Year |
Certificate | CE ISO |
Type |
Examination Therapy Equipment |
Brand Name | Chenwei |
Model Number | Beta 15 |
Place of Origin | Guangdong, China |
Product name | 15inch patient monitor |
Standard | ECG, SPO2, NIBP, Temp, Resp., HR |
Optional | EtCO2, 2IBP, Massimo SPO2, Printer, etc. |
Display | 15 inch TFT screen |
Optional Accessories | Aluminum trolley, wall mount stand |
Size | 300*170*305 mm |
Warranty | 1 Year |
Certificate | CE ISO |
Type |
Examination Therapy Equipment |
Features
|
Specification | |
Brand | PHILIPS |
Model | Efficia CM12 |
Display Size | 12″ LCD |
Resolution | 1280 x 800 |
Basic Parameter | ECG, SPO2, NIBP |
Temperature Range | 0–40°C (32–104°F) |
Humidity Range | 15–95% Relative Humidity |
Ingress Protection | IP21 |
Power Consumption | < 75 Watts. |
Weight | < 5.0 kg (11.0 lb). |
Indicator | Alarm, ON, Error, External Power & Battery |
USB 2.0 & RS232 | Available |
ETCO2 | Optional |
IBP | Optional |
Cardiac Output (CO) | Optional |
Specification | |
Brand | PHILIPS |
Model | IntelliVue MX 430 |
Country of Origin | Germany |
Display Size | 12″ LCD |
Resolution | 1280 x 800 |
Basic Parameter | ECG, SPO2, NIBP |
Temperature Range | 0–40°C (32–104°F) |
Humidity Range | 15–95% Relative Humidity |
Ingress Protection | IP21 |
Power Consumption | <70 W average |
Weight | 6.6 kg (14.6 lb) |
Indicator | Alarm, ON, Error, External Power & Battery |
USB 2.0 & RS232 | Available |
ETCO2 | Optional |
IBP | Optional |
Cardiac Output (CO) | Optional |
Product Name | Patient Monitor |
Brand | RMS |
NIBP Measurement range | 10-300mmHg |
Pulse Rate Range | 20-254bpm |
Usage/Application | Hospital |
Display | 8 Inch |
Display Size | 12.1″ |
Display color | TFT color Display |
Product Name | Patient Monitor |
Brand | Yonker |
Size | 6.9 * 11.6 * 5.7 inch |
Weight | 4.4 lb |
Battery | 11.1V 2000mAh rechargeable lithium battery |
Standard configuration | SpO2, PR/HR, NIBP, ECG, RESP |
Optional Configuration | TEMP/EtCO2, Nellcor SpO2, Thermal Printer |
LH-800 Oil-Free Air Compressor unit-Two
Bioland E122 Infrared Thermometer White