| Name | ACCU-CHECK |
| Item Type | Blood Glucose |
| Commodity Quality Certification | CE |
| Model Number | Accu-Chek Active |
| Size | 104 x 52 x 21 mm |
| Material | Plastic |
| Item Type | Blood Glucose Test Strips |
| is_customized | Yes |
| Type | Portable |
| Model Number | Accu-Chek Active |
| Material | ABS |
| Specification | 104 x 52 x 21 mm |
| Product categories | Home blood glucose meter |
| Name | ACCU-CHECK |
| Item Type | Blood Glucose |
| Commodity Quality Certification | CE |
| Model Number | Accu-Chek Active |
| Size | 104 x 52 x 21 mm |
| Material | Plastic |
| Item Type | Blood Glucose Test Strips |
| Customized | Yes |
| Type | Portable |
| Model Number | Accu-Chek Active |
| Material | ABS |
| Specification | 104 x 52 x 21 mm |
| Product categories | The home blood glucose mete |
| Brand Name | sinocare |
| Model Number | safe AQ smart |
| Certification | CE |
| Place of Origin | China |
| MOQ | 3000 |
| Delivery Time | 30 working days |
| Testing | FAD-GDH System |
| Blood sample | Fresh capillary whole blood, venous whole blood |
| Calibration sample | Venous plasma |
| Test range | 20-600 mg/dL (1.1-33.3 mmol/L) |
| Fast Test time | 5s |
| Tiny Blood volume | 0.6ul sample size |
| HCT | 30-60% |
| Expiry date | 24 months |
| Memory | 10 test results |
| Battery life | Up to 1000 tests |
| Model | Safe AQ smart |
| Unit | mg/dL; mmol/L |
| Commodity Quality Certification | 3C,3E |
| Test strip | GS300 |
| Coding | Smart code key calibration |
| Enzyme / Measurement technology | GOD / Electrochemical sensor |
| Blood sample source | Capillary whole blood |
| Minimum sample volume | 1.4 microliters (0.0014c.c.) |
| HCT range | 30 – 55% |
| Measuring range | 10 – 600mg/dL (0.6 – 33.3 mmol/L) |
| Meter dimensions (L x W x H) | 85.0 x 58.0 x 22.0 mm (3.34 x 2.28 x 0.86 inch) |
| Display area (L x W) | 39.0 x 38.0 mm (1.53 x 1.49 inch) |
| Weight (with battery) | 85g |
| Power supply | Two 1.5V AAA batteries |
| Memory capacity | 300 blood glucose test results with date and time |
| Operating temperature | 10 – 40°C (50 – 104°F) |
| Operating relative humidity | 10 – 90% |
| Meter storage conditions | -10 – 60°C (14 – 140°F) |
| Test strip storage conditions | 4 – 30°C (39 – 86°F), < 90% relative humidity |
| Accuracy | 95% of the measured glucose values shall fall within either |
| Glucose concentrations < 5.5mmol/L (100mg/dL), difference within ± 0.83mmol/L (15mg/dL) | |
| Glucose concentrations ≥ 5.5mmol/L (100mg/dL), bias within ± 15% | |
| Precision | Glucose concentrations < 5.5mmol/L (100mg/dL), SD < 0.28mmol/L (5mg/dL) |
| Glucose concentrations ≥ 5.5mmol/L (100mg/dL), CV < 5% |
| Model | GluNEO Lite |
| Brand | Infopia |
| Sample Type | Capillary and/or venous whole blood |
| Sample Volume | 0.5 µL |
| Test Range | 0.6 ~ 33.3 mmol/L |
| Reading Time | 5 seconds |
| Calibration | Plasma – Equivalent |
| Hematocrit | 20 ~ 65% |
| Altitude | ≤3048m (10,000 ft) |
| Operating Temperature | 10 ~ 40°C (50 ~ 104°F) |
| Operating Humidity | 10 ~ 90% |
| Strip Storage Temperature | 2 ~ 30°C (36 ~ 86°F) |
| Display Type | |
| Dimensions | 96 x 56 x 24 (mm) |
| Weight | 58±1g (including battery) |
| Power Rating | 3V Li-Battery (CR2032) x 2 |
| Battery Life | 1,000 running tests |
| PC Connection | USB Connection |
| Specifications of Blood Sugar Monitor – Glucometer + 10 Free Test Strips | |
| Product Line | UNLIMITED PRIMO |
| Weight (kg) | 0.2 |
| Colour | Black |
| Main material | Plastic |
| Skin Type | All Skin Types |
| Product Name | Blood Glucose Monitoring Syestem |
| Brand | Bionime |
| Test strip | GS700 |
| Coding | Auto-coding |
| Enzyme / Measurement technology | GDH / Electrochemical sensor |
| Blood sample source | Capillary, venous, arterial and neonatal whole blood |
| Minimum sample volume | 0.75 µL |
| HCT range | Glucose concentrations ≦ 11.1mmol/L(200mg/dL), HCT range 20 – 70% |
| Glucose concentrations > 11.1mmol/L(200mg/dL), HCT range 20 – 60% | |
| Measuring range | 0.6 – 33.3 mmol/L (10 – 600mg/dL) |
| Meter dimensions (L x W x H) | 82.0 x 45.0 x 15.5 mm (3.22 x 1.77 x 0.61 inch) |
| Display area (L x W) | 34.0 x 27.5 mm (1.09 x 1.34 inch) |
| Weight (with battery) | 43.0 ± 5 g |
| Power supply | 1 CR2032 battery |
| Memory capacity | 500 test results with date and time |
| Operating temperature | 6 – 44℃ (43 – 111°F) |
| Operating relative humidity | 10 – 90% |
| Meter storage conditions | -10 – 60°C (14 – 140°F) |
| Test strip storage conditions | At 4 – 30°C (39 – 86°F), and below 90% relative humidity |
| Bluetooth version (For GM700SB) | 4 |
| Accuracy | For glucose concentrations < 5.5 mmol/L (100 mg/dL), |
| 95% of measured glucose values within ± 0.83 mmol/L (15 mg/dL) of reference measurements. | |
| For glucose concentrations ≥ 5.5 mmol/L (100 mg/dL), | |
| 95% of measured glucose values within ± 15% of reference measurements. | |
| Precision | For glucose concentrations < 5.5 mmol/L (100 mg/dL), SD < 0.28 mmol/L (5 mg/dL) |
| For glucose concentrations ≥ 5.5 mmol/L (100 mg/dL), CV < 5% |
| Brand Name | sinocare |
| Model Number | safe AQ smart |
| Certification | CE |
| Place of Origin | China |
| MOQ | 01 |
| Delivery Time | 3/4 daya |
| Testing | FAD-GDH System |
| Blood sample | Fresh capillary whole blood, Venous whole blood |
| Calibration sample | Venous plasma |
| Test range | 20-600 mg/dL (1.1-33.3 mmol/L) |
| Fast Test time | 5s |
| Tiny Blood volume | 0.6ul sample size |
| HCT | 30-60% |
| Expiry date | 24 months |
| Memory | 10 test results |
| Battery life | Up to 1000 tests |
| Model | Safe AQ smart |
| Unit | mg/dL; mmol/L |
| Commodity Quality Certification | 3C,3E |