Clavicle Brace is scientifically designed to immobilize, compress and ensure linear union of fractures involving the clavicle bone. It is used where neither neuro vascular disturbances are severe, nor surgery is required.
| ECG | Heart rate display range | 15bpm ~ 350bpm |
| Heart rate display accuracy | ± 1% or ± 2bpm, whichever is greater | |
| Sweeping speed | 12.5mm/s, 25mm/s, 50mm/s | |
| Sensitivity selection | 1/2, 5mm/mV ×1, 10mm/mV ×2, 20mm/mV | |
| CMRR | ≥ 89dB | |
| RESP | Measuring range | 0rpm~120rpm |
| Accuracy | ±5% or ±2 rpm | |
| Alarm limits setting range | 0rpm~120rpm | |
| TEMP | Measuring range | 25.0℃ ~45.0℃ |
| Measuring accuracy | ±0.2℃ | |
| Responding time | ≤150s | |
| NIBP | Measuring method | Oscillometric Technique |
| Measuring range | 0 mmHg~300mmHg | |
| Accuracy | Maximal mean difference | ±5 mmHg |
| Maximal standard deviation | 8 mmHg | |
| Measurement range | Adult | SYS 40 ~ 255 mmHg |
| MAP 20 ~ 215 mmHg | ||
| DIA 10 ~ 195 mmHg | ||
| Pediatric patient | SYS 40 ~ 200 mmHg | |
| MAP 20 ~ 165 mmHg | ||
| DIA 10 ~ 150 mmHg | ||
| Neonate | SYS 40 ~ 135 mmHg | |
| MAP 20 ~ 110 mmHg | ||
| DIA 10 ~ 95 mmHg | ||
| SpO2 | Measuring range | 35%~100% |
| Low perfusion capability | 0.4%~5% | |
| Accuracy | Not greater than 3% for SpO2 range from 70% to 100% | |
| PR | Measuring range | 30bpm~240bpm |
| Measuring accuracy | ±2bpm or ±2%, whichever |
| SIZE | INCHES | CM |
|---|---|---|
| Small | Below 34 | Above 85 |
| Medium | 34-40 | 85-100 |
| Large | 40-46 | 100-115 |
| X-Large | 46-52 | 115-130 |
| XX-Large | 52-58 | 130-145 |
| Product Name | Infrared Digital Thermometer |
| Brand | Co-healthy |
| Model | GW-100 |
| Type | Infrared Thermometer |
| Temperature Range | 20C to +55C, RH: <= 93% |
| Battery Life | 6 months |
| Accuracy | +/-0.2C |
| Response Time | 1 Second |
| Flexible Tip | Warranty claimable at India |
| Buzzer | YES |
| Memory Function | 32 sets |
| Usage / Application | Oral Rectal & Underarm |
| Measurement Range | 32C to 42.9C |
| Ambient Temperature | 16C to 35C |
| Relative Humidity | <= 85% |
| ROHS Certified | YES |
| CE Certified | YES |
| Object Mode | YES |
| Testing channel: | 1 channel |
| Sample incubation positions: | 5 |
| Reagent incubation positions: | 2 |
| Software timer: | 1 |
| Test wavelength: | 470nm |
| Sample volume: | 20uL-40ul |
| Reagent volume: | 20uL-40ul |
| Temp control precision: | 37±0.3℃ |
| Memory: | 10,000 test results |
| Notation of Result: | S, %, PTR, INR, g/L |
| Display: | LCD (192*64) |
| Output: | Built-in thermal printer |
| Input: | Keypad |
| Interface: | RS-232 |
| Power supply: | AC220V±15%, 50-60Hz |
| Working Condition: | Temperature 10℃-30℃, Humidity ≤80% |
| Dimension: | 270*270*115mm (L*W*H) |
| Net Weight: | 5Kg |
| Testing channel: | 2 channels |
| Analysis mode: | 2 different parameters analysis in the same time |
| Sample incubation positions: | 16 |
| Reagent incubation positions: | 4 |
| Software timer: | 2 |
| Test wavelength: | 470nm |
| Sample volume: | 20uL-40ul |
| Reagent volume: | 20uL-40ul |
| Temp control precision: | 37±0.3℃ |
| Memory: | 10,000 test results |
| Notation of Result: | S, %, PTR, INR, g/L |
| Display: | LCD (240*128) |
| Output: | Built-in thermal printer |
| Input: | Keypad |
| Interface: | RS-232 |
| Power supply: | AC220V±15%, 50-60Hz |
| Working Condition: | Temperature 15℃-30℃, Humidity ≤90% |
| Dimension: | 395*320*135mm (L*W*H) |
| Net Weight: | 6Kg |
| SIZE | INCHES | CM |
|---|---|---|
| Small | 7.2-8.5 | 18.3-21.6 |
| Medium | 8.5-9.8 | 21.6-24.9 |
| Large | 9.8-11.1 | 24.9-28.2 |
| X-Large | 11.1-12.4 | 28.2-31.5 |
| Product Specification | |
| Brand | COFOE |
| Place of Origin | CHINA |
| Model | KF-65B |
| Certification | 3C |
| Material | HDPE |
| Detection Range | 0.0KPa~40.0KPa |
| Pressure | 860hpa~1060hpa |
| Size | 105*140*65 mm |
| Weight | 300 gm |
| Application | Arm |
| Screen Size | 3.7 inch |
| Storage Data | 120 sets |
| Product Specification | |
| Brand | COFOE |
| Place of Origin | CHINA |
| Model | KF-TZ-30A |
| Material of Chestpiece | Zinc alloy |
| Material of Tube | PVC |
| Material of Binaural | Copper |
| Diameter of Head | 48 mm |
| Size | 300*130*40 mm |
| Weight | 500 gm |
| Product Specification | |
| Brand | COFOE |
| Place of Origin | CHINA |
| Model | KF-TZ-30A |
| Material of Chestpiece | Zinc alloy |
| Material of Tube | PVC |
| Material of Binaural | Copper |
| Diameter of Head | 48 mm |
| Size | 300*130*40 mm |
| Weight | 500 gm |
| Product Specification | |
| Brand | COFOE |
| Place of Origin | CHINA |
| Model | KF-TZ-30A |
| Material of Chestpiece | Zinc alloy |
| Material of Tube | PVC |
| Material of Binaural | Copper |
| Diameter of Head | 48 mm |
| Size | 300*130*40 mm |
| Weight | 500 gm |
| DEVICE NAME: | COMPUTERISED ECG, Complete on Trolley |
| Model Number: | ClECG 01 |
| Brand Name: | BIBEAT LTD |
| Origin: | Bangladeshi |
| Weight: | 25 Kg |
| Warranty: | 24 Months |
| DEVICE NAME: | PEDOG01 |
| Model Number: | ECG01 |
| Brand Name: | BIBEAT LTD |
| Origin: | Bangladeshi |
| Weight: | 8 Kg (Main Sensor) |
| Warranty: | 24 Months |
| Type | Pathological Analysis Equipment |
| Brand Name | Contec |
| Place of Origin | Hebei, China |
| Model Number | 8000G |
| Instrument classification | Class II |
| Product name | Stress test ecg machine |
| Lead | Standard 12 leads |
| Noise level | ≤15μVp-p |
| Safety type | Class II Type CF with defibrillation protection |
| ECG | Lead mode: 3-lead or 5-lead Lead selection: I, II, III, aVR, aVL, aVF, V Waveform: 5-lead, 2-lead, 1-lead Gain: 2,5mm / mV, 5,0mm / mV, 10mm / mV, 20mm / mV, 40mm / mV Scanning speed: 12,5mm / s, 25mm / s, 50mm / s |
| HR: | Measurement and alarm range: 15~350bpm Precision: ±1% or ±1bpm, whichever is higher alarm accuracy: ± 2bpm Resolution: 1bpm ST-segment monitoring: measurement and alarm range: -2.0mV~+2.0mV Precision: -0.8mv~+0.8mv ±0.04mv or ±10%, whichever is higher Other range: unspecified arrhythmic analysis: ASYSTOLE, VFIB / VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACH |
| RESPIRATION | Method: R-F(RA-LL) Respiration rate: measurement and alarm range: 0~150rpm Resolution: 1 rpm Respiration accuracy: ±2 rpm Alarm accuracy: ±3 rpm Apnea alarm: 10~40s Scanning speed: 6.25 mm / s, 12.5 mm / s, 25 mm / s. |
| NIBP | Method: Oscillometry Mode: Manual / AUTO / Continuous Measurement period in AUTO mode: 1/2/3/4/5/10/15/60/90/120/240/480/960 minutes Continuous mode measurement interval: 5 minutes Measurement and warning range: 10 ~ 270 mmHg Resolution: 1 mmHg Cuff stress accuracy: ±3 mmHg Measurement accuracy: maximum mean deviation: ±5 mmHg Maximum standard deviation: 8 mmHg Over-pressure protection: adult mode |
| SpO2 | Measurement and warning range: 0 ~ 100 percent resolution: 1 percent accuracy of measurement: 70 percent ~100 percent: ±2 percent; 0 percent ~69 percent: unspecified. |
| PR | Measuring and alarm range: 30 ~ 250 bpm Measuring accuracy: ±2 bpm or ±2%, whichever is higher |
| TEMP | Channel: dual-channel Measurement and alarm range: 0 ~ 50ºC Resolution: 0.1 ºC Accuracy: ±0.1 ºC |
| EtCO2 | Method: Sidestream or Mainstream CO2 measurement range: 0~150mmHg CO2 resolution: 0~69mmHg: 0.1mmHg 70~150mmHg CO2 accuracy: 0.25mmHg CO2 accuracy: 0~40mmHg: ±2mmHg 41~70mmHg: ±5 percent 71~100mmHg: ±8 percent 101~150mmHg CO2 accuracy: ±10 percent AwRR accuracy: ±1 rpm Apnea alarm: yes. |
| IBP | Channel: dual-channel label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measurement and warning range: -10~300 mmHg Resolution: 1 mmHg Precision: ±2% or 1 mmHg, whichever is higher Power supply: AC 100-240V, 50/60Hz Safety classification: Class I, CF defibrillation-proof component added. |
| ECG | Lead mode: 3-lead or 5-lead Lead selection: I, II, III, aVR, aVL, aVF, V Waveform: 5-lead, 2-lead, 1-lead Gain: 2,5mm / mV, 5,0mm / mV, 10mm / mV, 20mm / mV, 40mm / mV Scanning speed: 12,5mm / s, 25mm / s, 50mm / s |
| HR: | Measurement and alarm range: 15~350bpm Precision: ±1% or ±1bpm, whichever is higher alarm accuracy: ± 2bpm Resolution: 1bpm ST-segment monitoring: measurement and alarm range: -2.0mV~+2.0mV Precision: -0.8mv~+0.8mv ±0.04mv or ±10%, whichever is higher Other range: unspecified arrhythmic analysis: ASYSTOLE, VFIB / VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACH |
| RESPIRATION | Method: R-F(RA-LL) Respiration rate: measurement and alarm range: 0~150rpm Resolution: 1 rpm Respiration accuracy: ±2 rpm Alarm accuracy: ±3 rpm Apnea alarm: 10~40s Scanning speed: 6.25 mm / s, 12.5 mm / s, 25 mm / s. |
| NIBP | Method: Oscillometry Mode: Manual / AUTO / Continuous Measurement period in AUTO mode: 1/2/3/4/5/10/15/60/90/120/240/480/960 minutes Continuous mode measurement interval: 5 minutes Measurement and warning range: 10 ~ 270 mmHg Resolution: 1 mmHg Cuff stress accuracy: ±3 mmHg Measurement accuracy: maximum mean deviation: ±5 mmHg Maximum standard deviation: 8 mmHg Over-pressure protection: adult mode |
| SpO2 | Measurement and warning range: 0 ~ 100 percent resolution: 1 percent accuracy of measurement: 70 percent ~100 percent: ±2 percent; 0 percent ~69 percent: unspecified. |
| PR | Measuring and alarm range: 30 ~ 250 bpm Measuring accuracy: ±2 bpm or ±2%, whichever is higher |
| TEMP | Channel: dual-channel Measurement and alarm range: 0 ~ 50ºC Resolution: 0.1 ºC Accuracy: ±0.1 ºC |
| EtCO2 | Method: Sidestream or Mainstream CO2 measurement range: 0~150mmHg CO2 resolution: 0~69mmHg: 0.1mmHg 70~150mmHg CO2 accuracy: 0.25mmHg CO2 accuracy: 0~40mmHg: ±2mmHg 41~70mmHg: ±5 percent 71~100mmHg: ±8 percent 101~150mmHg CO2 accuracy: ±10 percent AwRR accuracy: ±1 rpm Apnea alarm: yes. |
| IBP | Channel: dual-channel label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measurement and warning range: -10~300 mmHg Resolution: 1 mmHg Precision: ±2% or 1 mmHg, whichever is higher Power supply: AC 100-240V, 50/60Hz Safety classification: Class I, CF defibrillation-proof component added. |
| Type | Pathological Analysis Equipment |
| Brand Name | CONTEC |
| Place of Origin | Hebei, China |
| Model Number | ECG1200G |
| Instrument classification | Class II |
| Name | CONTEC ECG |
| Trade | Trade assurance service provided |
| Weigh | 3.2Kg |
| Dimension | 340mm(L) * 320mm(W) * 85mm(H) |
| Power supply | AC/DC |
| AC | 100V~240V(50/60Hz) |
| DC | 14.8V/3500mAh rechargeable lithium battery |
| Paper size | 210mm(W)*20m(L) |
| Certificate | CE ISO FDA |
| Type | Pathological Analysis Equipment |
| Brand Name | CONTEC |
| Place of Origin | Hebei, China |
| Model Number | ECG1200G |
| Instrument classification | Class II |
| Name | CONTEC ECG |
| Trade | Trade assurance service provided |
| Weigh | 3.2Kg |
| Dimension | 340mm(L) * 320mm(W) * 85mm(H) |
| Power supply | AC/DC |
| AC | 100V~240V(50/60Hz) |
| DC | 14.8V/3500mAh rechargeable lithium battery |
| Paper size | 210mm(W)*20m(L) |
| Certificate | CE ISO FDA |
| Brand Name | CONTEC |
| Model Number | ECG300G |
| Place of Origin | Hebei, China |
| Instrument classification | Class II |
| Type | Examination Therapy Equipment |
| Certificate | CE ISO FDA SFDA ROHS |
| Product name | 12 Lead ECG 3 channel |
| Weigh | 1.6Kg |
| Dimension | 315mm(L) *215mm(W) * 77mm(H) |
| Display | 3.5″ TFT Color LCD display |
| Optional | The software which can transfer data to PC |
| Multi-language | interface and report |