Product Specification | |
Brand | Mindray |
Application | Hospital, Diagnostic |
Model | Benheart R12 |
Place of Origin: | Guangdong, China (Mainland) |
Certification | CE ISO FDA |
Lead | 12 |
Channel | 12 |
Monitor | 8 inch |
Frequency response | 05 Hz to 150 Hz with notch at 50Hz |
Filter | DSP |
Input impedance | 10 MΩ |
Time constant | > 3.2 sec |
A/D conversion | 12 bit |
Noise | < 20μV |
p-p | |
Leakage current | < 10 μA |
Patient isolation | Optical isolation |
Gain | 5, 10 & 20 mm/mV selectable. |
CMRR | > 120 dB |
Sweep speed | 25.0 mm/S. |
Accuracy of HR | +/- 2 BPM. |
Sampling Frequenc | 250 samples per second simultaneous |
Power | 230V/220, 50Hz, 15A |
Power consumption | 1.5KVA |
Incline Range | 0-22% |
Dimension | L X W – 2055 X 750 mm |
Walking Area | 1440 X 500mm |
Weight | 100Kg |
Patient Weight | Up to 250kg |
Belt Speed | Smooth, 0-15Kmph |
Frequency response | 05 Hz to 150 Hz with notch at 50Hz |
Filter | DSP |
Input impedance | 10 MΩ |
Time constant | > 3.2 sec |
A/D conversion | 12 bit |
Noise | < 20μV p-p |
p-p | |
Leakage current | < 10 μA |
Patient isolation | Optical isolation. |
Gain | 5, 10 & 20 mm/mV selectable. |
CMRR | > 120 dB |
Sweep speed | 25.0 mm/S. |
Accuracy of HR | +/- 2 BPM. |
Sampling Frequency | 250 samples per second simultaneous |
Storage | 12 lead unaveraged ECG, 10-second Rhythm strips of 12 leads, Medians after every 8 sec along with HR, BP and fiducial points, full disclosure of entire test |
Power | 230V/220, 50Hz, 15A |
Power consumption | 1.5KVA |
Incline Range | 0-22% |
Dimension | L X W – 2055 X 750 mm |
Walking Area | 1440 X 500mm |
Weight | 100Kg |
Patient Weight | Up to 250kg |
Belt Speed | Smooth, 0-15Kmph |
Product | PC Based ECG |
Brand | BRITEMED |
Patient Leads: | 12 -lead electrocardiogram |
Sensitivity: | 5, 10, 20,40mm/mV |
Sampling Rate: | 1000 samples per second |
Low Cut Filter: | 0.05 Hz, 0.15 Hz, 0.3 Hz |
High Cut Filter: | 30 Hz, 150 Hz, 250 Hz, off |
Hum Filter: | 50 Hz, 60 Hz, off |
Common Mode Rejection: | > 90dB |
Sweep Speed: | 25mm/s |
Printing Paper Size: | A4 |
HR Measurement Range: | 30BPM_300BPM, Accuracy: ± 1BPM |
Defibrillator Protection: | Yes |
Pacing Pulse Detection: | Yes |
Power Supply: | 5V/0.3A (supplied from PC via USB cable) |
Dimensions (L x W x H): | 85 x 60 x 23.2mm |
Weight: | 157.5 g |
Operating Temperature: | 10°C_40°C |
Storage Temperature: | -20°C_50°C |
System Requirements OS: | Microsoft Windows 7 (32-bit/64-bit) or newer OS is required. |
PC display resolution: | 1280 x 768 (min) |
Specification | |
Brand | PHILIPS |
Model | PageWriter TC20 |
Warranty | 1 Year |
Display | 6.5″ Touch Screen |
Resolution | 640×480 |
Printing Resolution | 200×500 dpi |
Printing Paper Size | A4 |
Algorithm | DXL ECG |
Interpretive Statement | More Than 600 |
Graphical ST Presentation | Available |
Weight | 8.6 Kg Including Battery |
Product Name | RMS Portable EEG Machine |
Model | Maximus 32 Channel EEG |
Brand Name | RMS |
Number of Channels | 24 |
Type | Portable, Video EEG, USB Powered |
Noise | 0.5 |
Amplifier interface | USB |
Application | Hospital |
Brand | RMS |
Power Supply | USB POWERED |
Product Name | RMS Portable EEG Machine |
Model | Maximus 32 Channel EEG |
Brand Name | RMS |
Number of Channels | 32 |
Type | Portable, Video EEG, USB Powered |
Noise | 0.5 |
Amplifier interface | USB |
Application | Hospital |
Brand | RMS |
Power Supply | USB POWERED |
Recording Leads | 12 standard leads: I, II, III, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6 | ||||||||
Recording Channel | 12-ch x 1, 6-ch x 2, 6-ch x 2+1R, 3-ch x 4, 3-ch x 4+1R, 3-ch x 4+3R (R: Rhythm) | ||||||||
Recording Lead Group | Standard / Cabrera / Nehb / User-selectable group | ||||||||
Recording Mode | Auto, Manual, Rhythm, Periodic, Auto Start, Elapsed, Calibration(1mV), Copy, TPH test | ||||||||
Full Disclosure Report | Min. 10 sec ~ Max. 10 min. by user set / Manual mode | ||||||||
Recording Length | Min. 3 sec ~ Max. 85 sec. by user select ( Auto mode only ) | ||||||||
Recording system | Thermal printer head ( 8 dots/mm) / 203 (vertical) x 508 (horizontal) dpi | ||||||||
Recording Thermal Paper | Type | Roll type | Z-folder Option(option) | ||||||
CARDIPIA400H | Standard | Fax paper | Folding paper size : | ||||||
110 mm x 30 m | Grid record | 110 mm (L) x 60 mm (W) x 400 sheets | |||||||
CARDIPIA800H | 216 (or 210) mm | Grid record | Folding paper size : | ||||||
x 30 m | 210 mm (L) x 60 mm (W) x 400 sheets | ||||||||
Sensitivity (mm/mV) | 2.5, 5, 10, 20, 40, Auto | ||||||||
Interpretation (option) | Adult / Pediatric, Mean cardiac cycle with segment and measurement | ||||||||
Stress ECG I/F (option) | Wire (RS232/USB) / Bluetooth. Treadmill/Ergometer and PC stress ECG S/W are required | ||||||||
Recording Speed (mm/sec) | Auto record | Manual record | |||||||
5, 10, 12.5, 25, 50, 100 | 25, 50 | ||||||||
Display | Color TFT 7” LCD (Viewing area : 154.08mm x 85.92mm), Dots : 800 x 480 | ||||||||
Option Color TFT 7” Non-touch screen LCD (Viewing area: 154.08mm x 85.92mm), Dots: 800 X 480 | |||||||||
Option Color TFT 6.5” Non-touch screen LCD (Viweing area:154.08mm x 85.92mm), Dots: 800 X 400 | |||||||||
Display Channel (Ch) | 12 (6-ch x 2), 6 (3-ch x 2), 3 (3-ch x 1), 4 (2-ch x 2), 2 (2-ch x 1), 1 (1-ch x 1) | ||||||||
QRS Beat Display & Sound | 30 ~ 240 bpm on real time. | ||||||||
Alarm Display and Sound | Lead-off detection for individual 10 lead, Battery level, Paper empty, HR. | ||||||||
Key Operation | Alphanumeric PC key by membrane and LCD touch screen | ||||||||
Calibration Signal | Sensitivity and frequency response test by using an internal 1 mV | ||||||||
Language | English / Spanish / French / Russian / Turkish / Mongolian / others by user request | ||||||||
ECG Data Acquisition | Simultaneous 12-lead ECG | ||||||||
Input Impedance | Greater than 100 MΩ per 10 Hz | ||||||||
A/D Resolution | 16 bits (0.17 µV/bit) Option : 24bits (1.25 µV/bit) | ||||||||
A/D Sampling Rate | 8,000 samples/8-lead/sec. | ||||||||
CMRR | Greater than 100 dB | ||||||||
Frequency Response | 0.05 ~ 200 Hz ( -3dB unfiltered ) | ||||||||
Time Constant | Greater than 3.2 sec. | ||||||||
Digital Filter | Drift filter | Muscle Filter | AC filter | High-frequency filter | |||||
0.5Hz | 25 / 35 Hz | 50 / 60 Hz | 75 / 100 / 150 / 200 Hz | ||||||
Pace Maker Detection | Option | ||||||||
Arrhythmia Detection | Auto extend recording time to 20 ~ 60 sec by Ventricular Tachycardia and Bradycardia | ||||||||
Data Management | Save / Delete / Copy / Review / Transfer / Measure | ||||||||
Performance | AAMI standard requirements | ||||||||
Data Transfer I/F to HIS | USB memory stick / USB port / Ethernet LAN / Bluetoot (option) / WiFi (option) | ||||||||
Data Save Memory (10 sec) | Internal memory: Standard 4,000 records / Optional SD card (12,000 records per 1GB) / Optional external USB memory stick (12,000 records per 1GB) | ||||||||
TRISMED PCNet S/W | Via Wire USB / Bluetooth / USB memory / LAN/WiFi | ||||||||
HIS Data I/F | HL7 / XML / SCP / PDF /JPG/ PNG / DICOM(PACS) | ||||||||
External Device I/F | Barcode Reader / Magnetic card reader / printer :HP PSC1310 series, HP LeserJet Pro M201 M202 series | ||||||||
Patient Leakage Current | Less than 10μA | ||||||||
Electrical Safety | Class I (Degree of protection against electrical shock) | ||||||||
Defibrillation proof (5000VDC) based on type CF applied part | |||||||||
Complied IEC60601-1 :2005( 3rd edition), IEC60601-2-25:2011, IEC60601-1-2:2007 | |||||||||
Operation Power | AC | 100 ~ 240VAC ±10 % ~50/60 Hz free voltage | |||||||
Battery | Built-in rechargeable battery. NiMH19.2V (2200mA) / 420 reports (150 min) per 12-ch x 1 (5 sec) auto record by fully charged battery | ||||||||
Dimension (mm) | CARDIPIA400H | 313 (L) x 252 (W) x 85 (H) | |||||||
CARDIPIA800H | 333 (L) x 310 (W) x 105 (H) | ||||||||
Weight | CARDIPIA400H | 2.8 Kg with battery | |||||||
CARDIPIA800H | 3.3 Kg with battery | ||||||||
Temperature | Operating : +10 ~ +40 ℃ / Transport or Storage : -20 ~ +60 ℃ | ||||||||
Relative Humidity | Operating : 30~75 % (non-condensing) / Transport or Storage: 10~90 % (non-condensing) |
Product Name | ECG Machine |
Brand | Vcomin |
Model | 12 Channel |
Lead standard | 12leads |
Calibrating voltage: | 1mV±2% |
Voltage tolerance | ≥±500mV |
Inter-channel interference | ≤0.5mm |
Frequency response | 0.05~160Hz(-3db) |
Patient current leakage | <10μA |
Noise level | <15μVp-p |
Sensitivity valve: | ≤20μV |
Paper speed | |
Time constant | ≥3.2s 6.25,12.5, 25,50mm/s(±3%) |
Input dynamic range | ±10Vpp |
AC flter | 50Hz / 60Hz |
EMG filter | 25Hz / 45Hz |
Anti-drift filter | 0.15Hz(Adaptive) |
Sensitivity | 5,10,20mm/mV |
CMMR: ≥ | 120dB (with AC filter |
Input impedance | ≥50MΩ |
Input circuit current | ≤0.05μA |
Work mode | MAN、AUTO、ANALYSIS modes |
Lead acquisition | 12bit/1000Hz(synchronously 12 leads) |
Input circuit | floating; protection circuit against defibrillator effect |
Product Details | |
Model Number: | ZQ-1212-19 |
Brand Name: | Zoncare |
Origin: | China (mainland) |
Sampling rate: | 32000Hz (1ms) | Frequency Response: | 0.01 ~ 350Hz |
Time Constant: | ≥ 3.2s | A/D shift: | 24 bit |
CMRR: | ≥ 130dB | Input Impedance: | ≥ 50MΩ(10 Hz) |
Sensitivity: | 2.5, 5, 10, 20, 40 auto mm/mV±2% | Paper Size: | 80mm/20mm thermal roll paper |
Paper Speed: | 5, 6.25,12.5, 25, 50mm/s | Recording Mode: | Thermal array printer 8 dot/mm(vertical) 40 dot/mm(horizontal, 25mm/s) |
Electric Breast Pump BY 40 Beiurer (Germany)