ITEM #4007-2001 Duo-Gun Regular Kit Contains Duo-Gun Handpiece & Charger, GP Obturation Tips (23G, 4/box), Plunger Set, Multi-Tool, Safety Caps (2/pack), Plunger O-Ring Assembly (2/pack), Scrubbing Brush, Battery, Power Adapter, AC Power Cord |
Accessories: 4007-2010 Duo-Gun Handpiece 4007-2031 Duo-Gun Charger 4007-2080 Duo-Gun Battery 4007-2120 GP Obturation Tips (23G, 4/box) 4007-2121 GP Obturation Tips (25G, 4/box) 4007-2130 Safety Caps (2/pack) 4007-2140 Plunger Set 4007-2150 Plunger O-Ring Assembly (2/pack) 4007-2160 Multi-Tool 4007-2161 Scrubbing Brush 4007-2280 Adapter 4007-2287 AC Power Cord 181-101 Gutta Percha Obturator (Medium type, 100/bottle) |
Specifications | |
ECG | |
Lead type | 3-lead or 5-lead selectable |
Lead selection, 3-lead | I, II, III |
Lead selection, 5-lead | I, II, III, aVR, aVL, aVF, V |
HR measurement | Adult / pediatric: 15 bpm – 300 bpm Neonatal: 15 bpm – 300 bpm Step: 1 bpm |
HR accuracy | ±5 bpm or ±1 %, whichever is greater |
Arrhythmia | 21 calls |
ST measurement range | -2.5 mV – +2.5 mV |
Waveform speed | 6.25 mm/s,12.5 mm/s, 25 mm/s, 50 mm/s |
Gain selection | x 1/4, x 1/2, x 1, x 2, x 4, Auto |
Pacemaker detection | Yes |
Protection | Against electrosurgical interference and defibrillation |
Non-invasive blood pressure (NBP) | |
Method | Automatic oscillometric |
Parameters | SYS/DIA/MAP/Pulse Rate |
Operating mode | Manual/Auto/STAT |
Auto measure intervals | 3, 5, 10, 15, 30, 60, 90, 120, 240, 480 minutes |
Units | mmHg/kPa |
Cuff pressure range, adult / pediatric | 0 – 300 mmHg ( 0 kPa – 40.0 kPa) |
Cuff pressure range, neonate | 0 – 150 mmHg ( 0 kPa – 20.0 kPa) |
Systolic measurement range, adult/ pediatric | 30 mmHg – 254 mmHg (4.0 kPa – 33.9 kPa) |
Systolic measurement range, neonate | 30 mmHg – 135 mmHg (4.0 kPa – 18.0 kPa) |
Diastolic measurement range, adult / pediatric | 10 mmHg – 220 mmHg (1.3 kPa – 29.3 kPa) |
Diastolic measurement range, neonate | 10 mmHg – 110 mmHg (1.3 kPa – 14.7 kPa) |
MAP measurement range, adult / pediatric | 20 mmHg – 235 mmHg (2.7 kPa – 31.3 kPa) |
MAP measurement range, neonate | 20 mmHg – 125mmHg (2.7 kPa – 16.7kPa) |
Accuracy, maximum standard deviation | 8 mmHg (1.1 kPa) |
Accuracy, mean error | ±5 mmHg (±0.7 kPa) |
Pulse rate range | 40 bpm – 240 bpm |
Pulse rate accuracy | ±5bpm or ±5%, whichever is greater |
SpO2 (Philips SpO2 technology) | |
Measurement range | 0 – 100 % |
Accuracy | 70 % – 100 %, depends on sensor; 0 – 69 %, unspecified |
Waveform speed | 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s |
Pulse rate range | 30 bpm – 300 bpm |
Pulse rate accuracy | ±2 bpm or ±2%, whichever is greater |
Perfusion index | Yes |
Respiration (RESP) | |
Measurement method | Thoracic impedance |
Measurement range | 0 rpm – 150 rpm |
Accuracy | 0rpm – 120rpm: ±1 rpm; 121rpm – 150rpm: ±2 rpm |
Waveform speed | 6.25 mm/s,12.5 mm/s, 25 mm/s, 50 mm/s Accuracy undefined |
Gain selection | x 1/2, x 1, x 2 |
Apnea alarm | Yes, 10 – 60 s |
Work mode | Auto or manual (threshold) |
RESP lead | RA-LL |
Temperature (TEMP, 2-channel) | |
Measurement range | 0 – 50℃ (32℉ – 122℉) |
Resolution | 0.1℃ (0.2℉) |
Accuracy | ±0.1℃ (±0.2℉) (without sensor) |
Units | ℃ / ℉ |
Minimum measuring time | Attachable skin surface probe: less than 10 minutes Esophageal/rectal probe: less than 2 minutes |
Capnopgraphy (etCO2, optional) | |
Method | Microstream, infrared absorption (Oridion) |
Parameters | awRR, etCO₂, inCO₂ |
Measurement range | 0 – 99 mmHg (0 kPa – 13.2 kPa) |
Accuracy+C781, 0 – 38 mmHg (0 kPa – 5.1 kPa) | ±2 mmHg (±0.28 kPa) |
Accuracy, 39 mmHg – 99 mmHg (5.2 kPa – 13.2 kPa) | ± (5% of reading + 0.08% for every 1 mmHg (0.13 kPa) above 38 mmHg (5.1kPa) |
awRR range | 0-150 rpm |
awRR accuracy, 3 rpm – 70 rpm | ±1 rpm |
awRR accuracy, 71 rpm – 120 rpm | ±2 rpm |
awRR accuracy, 121 rpm – 150 rpm | ±3 rpm |
Invasive Blood Pressure | |
Accuracy | ±4 mmHg (0.53 kPa) or ±4 % of reading, whichever is greater |
Invasive blood pressure (IBP, 2-channel, optional) | |
Parameters | SYS/DIA/MAP/Pulse Rate |
Measurement range | -50 – 400 mmHg (-6.6 kPa – 53.3 kPa) |
Waveform speed | 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s |
Resolution | 1 mmHg (0.13 kPa) |
Units | mmHg/kPa/cmH₂O |
Transducer sensitivity | 5 uV/V/mmHg |
Pulse rate range | 30 bpm – 254 bpm |
Pulse rate accuracy | ±2bpm or ±2%, whichever is greater |
Sampling rate | 62.5 samples per second |
Recorder (optional) | |
Type | Built-in thermal recorder, 3 channels |
Print mode | Real-time recording, timed recording, alarm-activated recording |
Print speed | Auto, 12.5 mm/s, 25 mm/s, 50 mm/s |
Display | |
Type | Color TFT LCD, 4:3 |
Size | 10.4+611:631″ |
Resolution | 800 x 600 pixels |
Channels | Max 11 channels (auto waveform channel height adjustment) |
Power supply | |
AC power input | 100 – 240 VAC, 50/60 Hz |
Battery | Rechargeable Li-Ion battery Maximum 2.5 hour continuous monitoring (1 battery) |
Weight and dimensions | |
Net weight | Approx. 3.5 kg without battery |
Dimensions (w x d x h) | 316 mm x 265 mm x 131 mm (12.5 in. x 10.5 in. x 5.2 in.) |
Safety approval and quality system | |
Safety standard | IEC 60601-1-2:2014 |
Electromagnetic environment | IEC 60601-1-2:2000/A1:2014 |
Quality system | ISO9001 & ISO13485 certified CE marking according to the Council Directive 93/42/EEC |
Water proof | IPX1 |
Data review and storage | |
Data review and storage | 1600- NBP data, 1200 hr trend graph, 120 min full disclosure ECG 1, 200 – alarm & arrhythmia events |
External interface (standard) | |
External interface | ECG analog output VGA output Nurse call LAN USB |
Cardiac Output (optional) | |
Measurement method | Right heart thermodilution |
Measurement range | 0.1 l/min – 20.0 l/min |
Measurement accuracy | ±0.2 l/min or ±10 %, whichever is greater |
Blood temperature range | 27℃ – 43℃ (80.6℉ – 109.4℉) |
Blood temperature accuracy | ± 0.1℃ |
Injection temperature | 0℃ – 27℃ (32℉ – 80.6℉) |
Generator | DRE140 |
Max. Output | 40kW |
mA range | 10 ~ 500mA |
kV range | 40 ~ 125kV |
mAs range | 0.4 ~ 630mAs |
Power supply | 1Ø 220VAC 50/60Hz |
Exposure time | 0.004 ~ 10sec |
No. of APR | 216 |
Option | AEC |
X-ray tube | DRE140 |
Focal spot | 1.0/2.0mm |
Anode heat capacity | 100kJ (140kHU) |
Target angle | 16° |
Voltage range | 40 – 125kV |
Weight | 16kg |
Permanent filtration | 0.9mmAl |
Flat panel detector | DRE140 |
Scintillator | CSI |
Pixel pitch | 143um |
Resolution | 3.7lp/mm |
MTF | 36% (2.0lp/mm, 70kVp, 1×1) |
DQE | 0.7 |
Active Area | 43 x 43.9cm |
Pixel matrix | 3,008 x 3,072 |
AD conversion | 14 bits |
Energy range | 40 ~ 150kVp |
Power supply | 1Ø 100 ~ 240VAC 50/60Hz |
Dimension | 512 x 495 x 43mm |
Weight | 16kg |
Flat panel detector | DRE140 |
Scintillator | CSI |
Pixel pitch | 143um |
Resolution | 3.7lp/mm |
MTF | 36% (2.0lp/mm, 70kVp, 1×1) |
DQE | 0.7 |
Active Area | 43 x 43.9cm |
Pixel matrix | 3,008 x 3,072 |
AD conversion | 14 bits |
Energy range | 40 ~ 150kVp |
Power supply | 1Ø 100 ~ 240VAC 50/60Hz |
Dimension | 512 x 495 x 43mm |
Weight | 16kg |
Collimator | DRE140 |
Power supply | 1Ø 24VAC 50/60Hz |
Max. kVp shield | 35 x 35cm at SID 65cm |
Inherent filtration | 1.2mmAl |
Lamp luminosity | Over 160Lux |
Lamp time | 30sec |
Field size control | Manual |
Vertical travel distance | 1,400mm |
Transverse travel distance | 260mm |
Min. Tube height (from the floor) | 550mm |
Max. Tube height (from the floor) | 1,950mm |
Column rotation | ±90° |
Tube rotation | ±180° |
Longitudinal travel distance | 2,400 ~ 3,000mm ,(floor-ceiling fixed type), 1,500mm (floor fixed type) |
Power supply | 24VDC, 3A |
Weight | DRE140/150 |
Vertical travel distance | 1,400mm |
Min. Tube height (from the floor) | 400mm |
Max. Tube height (from the floor) | 1,800mm |
Power supply | 1Ø 16 ~ 24VAC 50/60Hz |
Weight | 120kg |
Application | DRE140/150 |
Tabletop size | 2,000 x 745mm |
Tabletop height | 670mm |
Tabletop material | Acryl |
Longitudinal Travel distance | ±280mm |
Transverse travel distance | ±140mm |
Bucky travel distance | ±230mm |
Max. patient weight | Max. 150kg |
Power supply | 1Ø 220VAC 50/60Hz |
Weight | 160kg |
Application | DRE140/150 |
Components | DRE140 with fixed dual FPD | DRE140 with portable FPD |
40kW Generator | ok | ok ok |
50kW Generator | ||
17″ x 17″ Flat panel detector | ok | |
14″ x 17″ Flat panel detector | ok | |
150kV X-ray tube | ||
125kV X-ray tube | ok | ok ok |
Basic Configuration | Tube stand, Bucky stand, Bucky table, PC & monitor, Acquisition Software,- upgradable to floor mounted Tube stand,- for international sales |
Type | Pathological Analysis Equipment |
Brand Name | Zoncare |
Place of Origin | Guangdong, China (Mainland) |
Model Number | iMAC120 |
Instrument classification | Class II |
Product name | iMAC120 portable price of ECG machine 12 channel |
Display | 10 inch HD LED Touch display |
Channel | 12-ch resting ECG |
Printing mode | Manual, Auto 3*4, 3*4+R, 3*4+3R, 6*2,6*2+1R,12*1 |
Measurement | Auto measurement and analysis, ECG reply |
Printing | Print A4 report by USB connecting with a Laser printer |
Storage | 1000 data built-in storage, support SD card or USB extended |
Other function | Qwerty keyboard and short cut function key input |
Size | 395mmx240mmx420mm |
Warranty |
12 months |
Product Name | ECG Machine |
Model | SE-1200 Express |
Brand | Edan |
Number Of Channels | 12 |
Dimension | 420x330x120 mm |
Power Supply | 100-240 V,50/60 Hz |
Battery Type | 14.8 V Rechargeable Built-In Li-ion Battery |
Paper Width | 216,210 mm |
Record Paper | Roll and Z-Fold |
Display | 10.1 inch LCD Screen |
Type | Digital |
Lead Selection | Automatic |
Brand Name | Yuwell |
Product | Electric Suction Machine |
Model Number | 8A-24D |
Maximum Negative Pressure | ≥90Kpa |
Input Power | 180VA |
Pumping Frequency | ≥20L/min |
Noise | ≤65dB(A) |
Reservor Capacity | 2500ml*2 |
Type | First-Aid Devices |
Product Name | Electro Surgical Unit |
Brand | MEDITOM |
Model | DT-400S |
DT | 400S |
Main Frequency | 400, 482KHZ ±10% |
Repetition | 33KHz ±10% |
H.F.L.C | Less than 150mA |
Patient leads to ground | Less than 0.01mA |
Classis to ground | Less than 0.1mA |
Power Source | 110/220V(±10%), 50/60Hz |
Dimensions (H×W×D) mm | 147×330×417mm |
Weight | 16Kg |
CE 3rd Edition | ISO9001, 13485 |
New Operation Mode | Monopolar/Bipolar SOFT COAG MODE |
D.R.M System | patient Return electrode Monitoring |
Product Name | Electro Surgical Unit |
Brand | MEDITOM |
Model | DT-400S |
DT | 400S |
Main Frequency | 400, 482KHZ ±10% |
Repetition | 33KHz ±10% |
H.F.L.C | Less than 150mA |
Patient leads to ground | Less than 0.01mA |
Classis to ground | Less than 0.1mA |
Power Source | 110/220V(±10%), 50/60Hz |
Dimensions (H×W×D) mm | 147×330×417mm |
Weight | 16Kg |
CE 3rd Edition | ISO9001, 13485 |
New Operation Mode | Monopolar/Bipolar SOFT COAG MODE |
D.R.M System | patient Return electrode Monitoring |
Cutting mode : Pure: | 350\150W \500 Load\1800V\1200\1.5 Crest Factor. |
Cutting mode : | Blend1:300\120 W \500 Load\ 2700\2000V\1.9 Crest Factor. |
Cutting mode : | Blend2: 200\80W \ 500 Load\ 2400\1700V\ 2.3 Crest Factor. |
Cutting mode : | Blend3:150\60W\ 500 Load\ 2900\3000V\ 3.1 Crest Factor. |
Coagulation mode : | Point: 100\70W\ 500 Load \ 4.600\3900V\ 4.5 Crest Factor. |
Coagulation mode : | Soft: 100\70W\ 500 Load\ 3600\3300V\ 6.1 Crest Factor. |
Bipolar | |
Coagulation mode : | Standard: 50\50W \ 100 Load \ 600V\ 1.5 Crest Factor. |
Accessory & Supply Connection | |
Finger-switch Pencil: | 1 |
Foot-Switch Pencil: | 2 |
Patient return electro code: | 1 |
Footswitch: | 1 |
AC power supply: | 1 |
Equipotential bonding: | 1 |
Power feature | |
Rate frequency: | 512kHz (110\240v Ac,60\50Hz). |
Isolated output: YES. | |
Quantitative display of contact area: | YES, for ”Split” type of neutral electro code. |
Contact area indicator lamp: | 10 lamps (one for 10% contact), alarm beep and flicker if contact<20%. |
Split\Solid neutral electrode definition: | YES, ”Split” or ”Solid” indicator lamp lights up. |
Adjustable alarm volume: | YES |
Operational duty cycle: | 10 seconds ON, 30 seconds OFF. |
Cooling method: | Convection |
Regulation | |
Type according to EN 60601-1: | CF. |
Protection class to EN 60601-1: | Class 1. |
Classification acc. | to MDD 93\42EEC: llb. |
Physical | |
Dimension (WxDxH): | 330*450*150mm. |
Weight: | 7 Kg. |
Monopolar | |
Cutting mode : | Pure: 400Watts\ 500 Load (OHMS)\ 2300V\ 1.5 Crest Factor. |
Cutting mode : | Blend1: 300 Watts\ 500 Load (OHMS)\ 2700V\ 2.1 Crest Factor. |
Cutting mode : | Blend2: 200Watts\ 500 Load (OHMS)\ 3.200V\ 2.5 Crest Factor. |
Cutting mode : | Blend3: 150Watts\ 500 Load (OHMS)\ 3.700V\ 3.1 Crest Factor. |
Coagulation mode : | Point: 120Watts\ 500 Load (OHMS)\ 5.600V\ 6.1 Crest Factor. |
Coagulation mode : | Soft: 120Watts\ 500 Load (OHMS)\ 3.400V\ 6.1 Crest Factor. |
Coagulation mode : | Spray: 120Watts\ 500 Load (OHMS)\ 8.500V\ 8.3 Crest Factor. |
Bipolar | |
Cutting mode : | Standard: 70Watts\ 200 Load (OHMS)\ 1.450V\ 1.5 Crest Factor. |
Coagulation mode : | Standard: 70Watts\ 500 Load (OHMS)\ 240V\ 1.5 Crest Factor. |
Coagulation mode : | Precise: 70Watts\ 200 Load (OHMS)\ 360V\1.5 Crest Factor. |
Accessory & Supply Connection | |
Finger-switch Pencil: | 2 |
Foot-Switch Pencil: | 1 |
Patient return electro code: | 1 |
Footswitch: | 1 |
AC power supply: | 1 |
Equipotential bonding: | 1 |
Power feature | |
Rate frequency: | 512kHz (110\240v Ac,60\50Hz). |
Isolated output: | YES. |
Quantitative display of contact area: | YES, for ”Split” type of neutral electro code. |
Contact area indicator lamp: | 10 lamps (one for 10% contact), alarm beep and flicker if contact<20%. |
Split\Solid neutral electrode definition: | YES, ”Split” or ”Solid” indicator lamp lights up. |
Adjustable alarm volume: | YES |
Operational duty cycle: | 10 seconds ON, 30 seconds OFF. |
Cooling method: | Convection |
Regulation | |
Type according to EN 60601-1: | CF. |
Protection class to EN 60601-1: | Class 1. |
Classification acc. | to MDD 93\42EEC: llb. |
Physical | |
Dimension (WxDxH): | 460*410*160mm. |
Weight: | 11.2 Kg. |
Type | Multi-function Home Use Fetal Doppler |
Brand Name | Elite |
Model Number | FD-643 |
Instrument classification | Class II |
System | Two audio output |
Certificate | CE ISO |
Display mode | LCD Display |
Continuous work | over 8 hours |
Product Name | Syringe Pamp |
Brand | ENMIND |
Syringe sizes | 5ml, 10ml, 20ml, 30ml, 50/60ml |
Flow rate accuracy | ±2% |
Flow rate | 0.1-1500 ml/h |
VTBI | 0-9999 ml |
Dose rate units | More than 12 Types |
Concentration calculate | Automatically |
Parameters enlarge | Support |
Purge | Support |
Titration | Support |
Bolus setting | Manual bolus, Programmable bolus |
KVO rate | 0.1-5.0 ml/h |
Infusion modes | 3 infusion mode |
Standby mode | Support, standby time 0-23h59m adjustable |
Drug library | Support, more than 60 |
Keypad lock | Support |
Brightness | Adjustable |
Alarm volume | Adjustable |
Occlusion levels | 3 levels |
Anti-bolus | Automatically |
Records | More than 2000 entries |
Alarms | VTBl near the end, VTBl infused, Pressure high, Battery nearly empty, Battery empty, No power supply, Reminder alarm, KVO finished |
Power supply | |
AC | 11ov-240V, 50/60Hz |
DC | 12V |
Battery life | Approx.12 hours (at 5ml/h flow rate with a new fully charged battery) |
Classification | Class l, CF |
Waterproof | IP24 |
Calibration | Automatically |
Display | 2.8-inch color TFT |
Input | Keypad |
Interface | MINI USB |
Wireless | WIFI ( optional ) |
Weight | Approx. 1 .7 kg |
EN-S7 Smart Syringe Pump is a very popular and high-quality medical product using all over the world by experts in hospital and diagnostics
Brand | ENMIND |
Alarm Volume | Adjustable |
Brightness | Adjustable |
Screen | 4.3-inch color touch screen |
Screen Lock | Avoid misoperation |
Purge | Remove the air bubble |
History Record | More than 5000 entries |
Standby Mode | Standby time 00-99h59m adjustable |
DPS | Real-time pressure display in graphically and numerically |
DPS | Real-time pressure display in graphically and numerically |
AC Power | 110V-240V, 50/60Hz |
External DC Power | 12V Lithium Polymer battery ll.lV 2600mAh |
Brand | ENMIND |
Operation System | Smart |
Modes | 7 infusion modes |
Rate range | 0.01ml/h- 1200ml/h (increments 0.01ml/h) |
Micro mode | 100ml/h to 1200ml/h |
VTBI | 0.01-9999ml – 0.01 steps |
Battery Life | 9h battery life |
Dimensions | 235(l)x 95(w) x 129(h)mm |
Design | Stackable |
Product Name | Portable ventilator |
Brand | ETERNITY |
Model | SH-210 |
Patient type | Adult & Pediatric |
Driven mode | Gas driven electronically controlled |
Working mode | pressure limited, time cycled, volume controlled |
Setting | Electronic Knob |
Ventilation mode | VCV, SIGH, SIMV+VCV, CPAP, SPONT |
Waveform | P-T, F-T, V-T, P-V Loop, V-F Loop |
Tidal volume | 0~1500ml |
Breathing rate | 4~100bpm |
I:E | 3:1~1:5 |
Trigger sensitivity | -2KPa~PEEP |
PEEP | 0~2KPa |
Oxygen | 50~100% |
Product Name | RMS Vega 201 Treadmill Test (TMT) |
Model | VEGA 201 |
Display Type | Digital |
Grade | Semi-Automatic |
Brand | RMS |
Supply | AC |
Minimum Order Quantity | 1 Unit |
Ultrasound frequency | 2.5 MHz Continuous Wave |
Acoustic Output | Low Power – exemption |
Audio bandwidth and power | 1.25-250 Hz, 100 mW(32Ω stereo headset) |
Fetal Heart Rate | Display: 3 digit FHR |
Range | 50-240 bpm |
Accuracy | ±1% or ±1 bpm whichever is greater |
Resolution | 1 bpm |
Power Supply | 3 x AAA 1.5V Alkaline |
Auto Shut off | About 2 mins no signal |
Unit Controls | Buttons: On/Off, Volume |
Operating temperature | 5 – 40°C |
Operating humidity | 30 – 80% |
Dimension | 296 (W) x 305.5 (H) x 92.5 (D) mm, approx. 2.9 kg |
Display | 7-segment LED 2 channels (HR, UC) |
Printer | Thermal array type Print speed: 1, 2, 3 cm/min Paper feeding function |
Power | Input: AC100 – 240v (50/60 Hz) Output: DC18v, 2.5A Consumption: 80w |
External Link | RS-232C: Program download Central (option) |
Fetal Heart Rate | Input Signal: Ultrasound pulsed doppler Ultrasound frequency: 1.0 MHz Intensity: FHR range: 50~240 BPM FHR accuracy: 120~160: ±1 BPM |
Uterine Contraction | External type Frequency response: DC ~0.5Hz Reference(zero) control Measurement range: 0~99 units |
Fetal Movement Measurement | Detection source: Ultrasound pulsed doppler |
Indicators | Heart rhythm with signal quality Alarm, printing on/off state AC power |
Sound | Doppler sound Alarms sound Information sound |
Setup | Alarm upper/low limit value Record speed, apper grid, fetal movement on/off, time/date, print contrast, auto print period |
Function | Event mark function Auto fetal movement detection |
Standard Accessories | Ultrasound doppler probe – 1 ea UC probe – 1 ea Event marker jack – 1 ea Printer paper – 2 rolls Power adaptor & cord – 1 ea Ultrasound gel – 1 ea Probe belt – 2 ea Operation manual – 1 ea Stand – 1 ea Basket – 1 ea Bag – Optional |
BMC P2 Nasal Pillow CPAP/BiPAP Mask