| Product Name | Fuji FCR Capsula XL II |
| Brand Name | Fuji |
| Model Number | Capsula 2 (CR-IR 356) and Drypix 2000 |
| Place of Origin | Japan |
| Supply Ability: | 1 Piece/Pieces per Month |
| Packaging Details | standard wooden package or upon your request |
| Port | OSAKA, JAPAN |
| Lead Time : | 5-15 days after the order confirmation |
| Category | Specifications |
| Tube | E7252X Focal spots: 0.6mm small (27kW) 1.2mm large (75kW) Anode heating unit: 300kHU Max. kV: 150kV Housing heat unit: 1250kHU |
| Tube stand | Type: Floor mounted with counterbalanced. Electromagnetic locks Travel ranges : Longitudinal : 180cm Vertical : 149cm (40 to 189cm from the floor level) Transverse : 24cm Tube arm angle : Horizontal axis : -90° ~ +90° Vertical axis : -90° ~ +90° LCD screen to display tube angle status. |
| Collimator | Type: manual Filtration : 0.1/0.2mm cooper & Aluminum – auto choice available by APR Exposure area to be identified through halogen light |
| SONTU FPD Technical Parameters | |
| Model | 14X17 |
| Detector type | Amorphous Silicon Flat Panel Detector |
| Scintillator type | GOS |
| Pixel Matrix/mm±0.5 | 350*426 |
| Resolution | 2496*3040 |
| Pixel Pitch/um | 140 |
| Limiting Resolution | ≥3.4Lp/mm |
| A/D Conversion/bit | 16 |
| Sync mode | Fixed integral |
| Imaging time/S | ≤2 |
| Image transmission | Gigabit Ethernet |
| Weight/kg±0.05 | 3.25 |
| Detector size/mm±0.5 | 462*384*16.3 |
| Power input of power box/V | 100~240VAC |
| Power | 22W |
| protection from electric shock | CLASS B |
| Ingress Protection | IP54 |
| Working temperature(℃) | 5~40 |
| Working humidity(%RH) | 15~90 |
| Storage temperature(℃) | -20~+50 |
| Storage humidity(%RH) | 10~90 |
| Irradiation hardness/GY | 150 |
| SONTU FPD Technical Parameters | |
| Model | 17X17 |
| Detector type | Amorphous Silicon Flat Panel Detector |
| Scintillator type | GOS |
| Pixel Matrix/mm±0.5 | 430*430 |
| Resolution | 3072*3072 |
| Pixel Pitch/um | 140 |
| Limiting Resolution | ≥3.4Lp/mm |
| A/D Conversion/bit | 16 |
| Sync mode | Fixed integral |
| Imaging time/S | ≤2 |
| Image transmission | Gigabit Ethernet |
| Weight/kg±0.05 | 4.08 |
| Detector size/mm±0.5 | 462*477*16.1 |
| Power input of power box/V | 100~240VAC |
| Power | 25W |
| protection from electric shock | CLASS B |
| Ingress Protection | IP54 |
| Working temperature(℃) | 5~40 |
| Working humidity(%RH) | 15~90 |
| Storage temperature(℃) | -20~+50 |
| Storage humidity(%RH) | 10~90 |
| Irradiation hardness/GY | 150 |
| Product Name | LED Light |
| Brand | Heal Force |
| Luminance (Lux) | (130.000 lux – 160.000 lux) X 2 |
| Color Temperatur (Kelvin) | 5100K±300K |
| Light field diameter (mm) | d10: ≥160; d50:≥50% X d10 |
| Focusing depth (mm) : | ≥ 800 |
| Color rendering index (RA) | 95±5 |
| Total irradiance | ≤ 1000W/m² Ee/Ec:≤6mW/m² |
| Power supply | AC 220 – 230V/50-6Hz, 110V 60Hz |
| Rated current | 0.68A+0.68A |
| Rated power | 150VA+90VA |
| Power of LED bulb | (1W high-power LED bulb) X 150pcs |
| Voltage of LED bulb : | Vf: DC 3.2V |
| Standard installation height (mm) | 2900 – 3100 |
| Carrying capacity for OR ceiling (Kg) | ≥ 500 |
| Weight (Kg) | 105 |
| Product Name | PC based Spirometer |
| Model | Helios 401 |
| Application | Hospital |
| Brand | RMS |
| Accuracy% | 0.5 +/- |
| Voltage | 220 V |
| Frequency | 50 Hz |
| Handset | 01 |
| Turbine Transducer | 01 |
| Software CD | 01 |
| USB cable | 01 |
| Reusable Mouth Pieces | 01 |
| Adult nose clip | 01 |
| Pediatric nose clip | 01 |
| carry bag | 01 |
| User Manual | 01 |
| Weight, | 8kg |
| Weight | with mobile stand 22 kg |
| Hammock Mattress | 58cm x 29cm |
| Skin Temp | Display 25 °C to 42 °C |
| Noise Level | < 55dBA |
| Screen | 3,1 inches LCD |
| Lamp Type | 10 pcs Blue Super LED |
| Effective Irradiance Area | 25 cm X 20 cm |
| SMPS | 9VDC 3,33 A |
| Intensity | > 60 µw/cm²/nm |
| Supply Voltage | 100-240 VAC 50-60 Hz |
| Product name: |
Infant Phototherapy Units |
| Brand Name: | Heal Force |
| Model Number: |
FY-GLQ-1L |
| Type: |
Infant Care Equipments |
| Certificates: |
CE, ISO |
| Packaging Details | Standard Export Wooden (No Timber) Packing with foam inside. |
| Product name: |
Infant Phototherapy Units |
| Brand Name: | Heal Force |
| Model Number: |
FY-GLQ-1L |
| Type: |
Infant Care Equipments |
| Certificates: |
CE, ISO |
| Packaging Details | Standard Export Wooden (No Timber) Packing with foam inside. |
| Display | 44.5*23mm LCD display |
| Ultrasound Intensity | <10mW/cm2 |
| Working Mode | Continuous Wave Doppler |
| Resolution | 1bpm,accuracy:±2bpm |
| Probe Frequency | 3.0Mhz |
| Measuring Mode | Real-Time FHR Display Mode, Average FHR Display Mode, Manual Mode |
| Effective radiating area of transducer | 208mm2±15% |
| Safety | The ultrasound is lower than the national ultrasonic power standard by over 50%. |
| Auto shut off | 1 minute without operation |
| Power consumption | < 0.8w |
| Size | 130mm (L) x 100mm (W) x 36mm (H) |
| Battery | 2pcs AA alkaline batteries |
| Power Supply | 2pcs AA alkaline batteries |
| Model Number | LH-800 |
| Brand Name | Lovage Medical |
| Place of Origin | Guangdong, China |
| Power Source | AC Power |
| Power | 850 W |
| Voltage | 220V/110V |
| Ampere | 3.8 A |
| Frequency | 50Hz/60Hz |
| Lubrication Style | Oil-free |
| Rated exhaust pressure | 0.8 Mpa |
| Mute | Yes |
| Dimension(L*W*H) | 850mm*440mm*750mm |
| Configuration | Portable |
| Weight | 60kg/65kg |
| Noise | 56-65 dB |
| Tank volume | 30 L |
| Rated exhaust flow | 81 L/min |
| Warranty | 1 Year |
| Product Specification | |
| Brand | Mindray |
| Application | Hospital, Diagnostic |
| Model | Benheart R12 |
| Place of Origin: | Guangdong, China (Mainland) |
| Certification | CE ISO FDA |
| Lead | 12 |
| Channel | 12 |
| Monitor | 8 inch |
| Product Name | Infusion Pamp |
| Brand | Mindray |
| Model | BeneFusion VP1 |
| Condition | New |
| Insulin infusion | Yes |
| Syringe | Yes |
| Ambulatory | Yes |
| PCA | Yes |
| Warranty | 12 month(s) |
| Product Name | Infusion Pump |
| Brand | Mindray |
| Model | SK-600I |
| Monitor | TFT color 3.0 Inches |
| Infusion volume | Accumulation of 0,1 – 9999,9 ml |
| Information | Flow rate, prism volume, accumulated infusion volume, pressure, power indicator, battery capacity, battery charge indicator |
| Status indicator | Stop, Run, Bolus, KVO |
| Alimentation | 100 – 240 VAC, 50/60 Hz |
| Temperature | 5 – 40° C for operation, -20 to 50 ° C for storage |
| Air pressure | 86 – 106 kPa for operation, from 50 to 106 kPa for storage |
| Humidity | 20% – 80%For operation, 10% – 95% for storage |
| Battery | Lithium polymer capacity 25 ml / h up to 2 hours of continuous operation |
| Brand | RMS |
| Product | C-ARM |
| Model | Corus 9 |
| Display | Digital |
| Operation Mode | Automatic |
| Type | Portable, Fixed, Digital |
| mA | 50 |
| Is It Portable | Portable |
| Application | Orthopedic |
| Condition | new |
| Brand | YK-8000B |
| Display | 12.1-inch high-resolution color TET LCD |
| Alarms | 3-level audio/visual |
| Working Capability | 2-hour |
| Battery | Built-in rechargeable lithium battery |
| Size | 12 * 11.4 * 6.4 inch |
| Weight | 8.8 lb |
| Electrical Specification | 100-240v AC, 50/60Hz, Max Input Power: 70VA |
| Battery | 11.1V 2200mAh rechargeable lithium battery |
| Standard configuration | SpO2, PR, NIBP, ECG, RESP, TEMP |
| Optional Configuration | Nellcor SpO2, 2-IBP, ETCO2, Touch screen, Built-in Thermal Printer |
| Various interfaces | standard screen, trend screen, oxy CRG screen, NIBP list screen, big front screen. |
| IBP | Method: Oscillometry |
| Modes: Manual/Auto/ Comtinuous | |
| Auto measure time: Adjustable | |
| Measurement range:10-270mmHg | |
| ECG | Lead mode: 3-lead or 5-lead |
| Lead selection: I;II;III,avR;avF;V | |
| Heart rate range: Adult:15-300bpm;Pediatric/Neonatal:15-300bpm | |
| ECG waveform: 2 channels | |
| Accuracy: ±1 bpm or ±1%,which is greater | |
| S-T segment detection; measurement range: 2.0mv~2.0mv | |
| Alarm: Yes, audible and visual alarm, alarm events review | |
| SPO2 | Measurement range:0-100% |
| Accuracy:70-100%,±2%,0-69%,upspecified | |
| Auto measure time: Adjustable | |
| Pulse Rate | Range:20-254bpm |
| Accuracy: ±3bpm | |
| Respiration | Method: RA-LL impedance |
| Range: Adult:0-120rpm;pediatric/neonatal:0-150rpm | |
| Apnca alarm: Yes | |
| Temperature | Range:0-500 |
| Accuracy: ± 0.10 | |
| Channel: Dual-channel |
| Display: | 10.4 Inch Multi-Parameter Color Patient |
| Monitor: | 2ch ECG, SpO2, NIBP, 2ch IBP, 2ch Temp, Respiration, Optional Built-in EtCO2 |
| Built-In EtCO2 Module: | Built-In EtCO2 Mode (EtCO2 module is inside of monitor Respironics sidestream module |
| Easy to use: | Selectable 5 waveform / 4 waveform / 3 waveform Display/Enabled / disabled /parameters, the color, and font of each parameter are changeable changeable |
| ECG Analysis: | 12 kinds of arrhythmia analysis ST Level & PVC count real-time display |
| IBP: | ABP / CVP / PAP / LAP |
| Multi-national Software: | English, French, German, Spanish, Italian, Portuguese |
| Transportable: | Up to 4 hours use with battery Less than 3 kg of lightweight |
| Quick start-up: | Less than 2 seconds |
| Trend data: | 72 hours of graphics and tabular trend Interface RS-232 port and LAN port |
Electronic Blood Pressure Monitor YE-680E