| Product Name | Fetal Monitor |
| Model | BT-350 |
| Brand | Bistos |
| Dimension | 80mm (H) X 330mm (L) X 280mm (D) |
| Application | Hospital |
| Screen rotating | 180 Degree |
| LCD display | 7″ wide TFT color LCD display |
| Product Name | High Flow Oxygen Therapy |
| Brand | BMC |
| Model | H-80A |
| Flow Monitoring | Adjustable |
| Flow Rate | 2L-80L/min |
| Oxygen Concentration Adjustable Range | 21%-100% |
| Temperature Output Range | 29c-37c |
| Temperature Adjustment Gear | 9 steps |
| Screen Size | 3.5 inches |
| Trend Review Function | 1, 3, 7 days |
| Oxygen Concentration Adjustable Range | 21%-100% |
| Oxygen Concentration Monitor | Adjustable |
| Temperature Monitoring | Adjustable |
| sPEEP Monitoring | Monitorable |
| Respiratory Rate Monitoring | Monitorable |
| Automatic Filter Replacement Function | Yes, can be set |
| Automatic Water Refills Tips | Yes |
| Humidity Compensation | 7 step adjustable |
| Sleep | 4 step adjustable |
| Hot Standby | Yes |
| ECG Leads | 12-leads (I, II, III, aVR-L-F, V1-6) |
| CMRR | 115 dB |
| Sampling Frequency | 500 or 1000 Hz/channel/storage |
| A/D Conversion | 24 bit |
| Resolution | < 1uV/LSB |
| Bandwidth | 0.05 – 150 or 300 Hz depending on the sampling rate |
| Pacemaker Detection | Hardware and software correlated detection with digital filter |
| Filters | Fully digital high-pass diagnostics filter; digital AC interference adaptive filter (50/60 Hz); digital low-pass filter (applied during display and printing stage) |
| Defibrillation Protection | AAMI/IEC standards |
| Front-End Performance | ANSI/AAMI IEC 60601-2-25:2011 |
| Safety | ANSI/AAMI ES1, Class I CF, CE0476 |
| ECG Storage | Internal memory 100 ECGs, an expansion for 1000 additional ECGs (optional) |
| Display | 4.3″ backlit LCD color display, displays the ECG waveform in real time |
| Thermal Printer | 8 dot/mm; 108mm; Z-fold 150mm paper |
| Manual Printing | 3 or 6 channels -5/10/25/50 mm/s |
| Automatic Printing | Standard or Cabrera; 3, 3+1, 6 channels |
| Patient Demographic, Global Measurements, Optional Interpretation (Glasgow University – Prof. MacFarlane) | |
| Keypad | Mechanical keypad with alphanumeric keys and function keys |
| Connectivity | USB device, LAN, 802.11g/n Wi-Fi (optional) |
| Patient Cable | Standard 15D, 10 electrodes |
| Data Export | PDF, XML (optional), GDT (optional), DICOM (optional), HL7 (optional) |
| Power Supply | Medical AC power-supply unit (100-240 VAC 50/60 Hz); internal rechargeable battery |
| Dimensions | 285 x 204 x 65 mm |
| Weight | 1.8kg with battery |
| Brand | Curative |
| Model | Cavent |
| Measured parameter | TEMP, ECG, RESP, NIBP, IBP, SpO2 |
| Applications | Intensive care |
| Configuration | Portable |
| Patient type | Pediatric |
| Screen size | 12 in |
| ECG | Heart rate display range | 15bpm ~ 350bpm |
| Heart rate display accuracy | ± 1% or ± 2bpm, whichever is greater | |
| Sweeping speed | 12.5mm/s, 25mm/s, 50mm/s | |
| Sensitivity selection | 1/2, 5mm/mV ×1, 10mm/mV ×2, 20mm/mV | |
| CMRR | ≥ 89dB | |
| RESP | Measuring range | 0rpm~120rpm |
| Accuracy | ±5% or ±2 rpm | |
| Alarm limits setting range | 0rpm~120rpm | |
| TEMP | Measuring range | 25.0℃ ~45.0℃ |
| Measuring accuracy | ±0.2℃ | |
| Responding time | ≤150s | |
| NIBP | Measuring method | Oscillometric Technique |
| Measuring range | 0 mmHg~300mmHg | |
| Accuracy | Maximal mean difference | ±5 mmHg |
| Maximal standard deviation | 8 mmHg | |
| Measurement range | Adult | SYS 40 ~ 255 mmHg |
| MAP 20 ~ 215 mmHg | ||
| DIA 10 ~ 195 mmHg | ||
| Pediatric patient | SYS 40 ~ 200 mmHg | |
| MAP 20 ~ 165 mmHg | ||
| DIA 10 ~ 150 mmHg | ||
| Neonate | SYS 40 ~ 135 mmHg | |
| MAP 20 ~ 110 mmHg | ||
| DIA 10 ~ 95 mmHg | ||
| SpO2 | Measuring range | 35%~100% |
| Low perfusion capability | 0.4%~5% | |
| Accuracy | Not greater than 3% for SpO2 range from 70% to 100% | |
| PR | Measuring range | 30bpm~240bpm |
| Measuring accuracy | ±2bpm or ±2%, whichever |
| DEVICE NAME: | COMPUTERISED ECG, Complete on Trolley |
| Model Number: | ClECG 01 |
| Brand Name: | BIBEAT LTD |
| Origin: | Bangladeshi |
| Weight: | 25 Kg |
| Warranty: | 24 Months |
| DEVICE NAME: | PEDOG01 |
| Model Number: | ECG01 |
| Brand Name: | BIBEAT LTD |
| Origin: | Bangladeshi |
| Weight: | 8 Kg (Main Sensor) |
| Warranty: | 24 Months |
| Type | Pathological Analysis Equipment |
| Brand Name | Contec |
| Place of Origin | Hebei, China |
| Model Number | 8000G |
| Instrument classification | Class II |
| Product name | Stress test ecg machine |
| Lead | Standard 12 leads |
| Noise level | ≤15μVp-p |
| Safety type | Class II Type CF with defibrillation protection |
| ECG | Lead mode: 3-lead or 5-lead Lead selection: I, II, III, aVR, aVL, aVF, V Waveform: 5-lead, 2-lead, 1-lead Gain: 2,5mm / mV, 5,0mm / mV, 10mm / mV, 20mm / mV, 40mm / mV Scanning speed: 12,5mm / s, 25mm / s, 50mm / s |
| HR: | Measurement and alarm range: 15~350bpm Precision: ±1% or ±1bpm, whichever is higher alarm accuracy: ± 2bpm Resolution: 1bpm ST-segment monitoring: measurement and alarm range: -2.0mV~+2.0mV Precision: -0.8mv~+0.8mv ±0.04mv or ±10%, whichever is higher Other range: unspecified arrhythmic analysis: ASYSTOLE, VFIB / VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACH |
| RESPIRATION | Method: R-F(RA-LL) Respiration rate: measurement and alarm range: 0~150rpm Resolution: 1 rpm Respiration accuracy: ±2 rpm Alarm accuracy: ±3 rpm Apnea alarm: 10~40s Scanning speed: 6.25 mm / s, 12.5 mm / s, 25 mm / s. |
| NIBP | Method: Oscillometry Mode: Manual / AUTO / Continuous Measurement period in AUTO mode: 1/2/3/4/5/10/15/60/90/120/240/480/960 minutes Continuous mode measurement interval: 5 minutes Measurement and warning range: 10 ~ 270 mmHg Resolution: 1 mmHg Cuff stress accuracy: ±3 mmHg Measurement accuracy: maximum mean deviation: ±5 mmHg Maximum standard deviation: 8 mmHg Over-pressure protection: adult mode |
| SpO2 | Measurement and warning range: 0 ~ 100 percent resolution: 1 percent accuracy of measurement: 70 percent ~100 percent: ±2 percent; 0 percent ~69 percent: unspecified. |
| PR | Measuring and alarm range: 30 ~ 250 bpm Measuring accuracy: ±2 bpm or ±2%, whichever is higher |
| TEMP | Channel: dual-channel Measurement and alarm range: 0 ~ 50ºC Resolution: 0.1 ºC Accuracy: ±0.1 ºC |
| EtCO2 | Method: Sidestream or Mainstream CO2 measurement range: 0~150mmHg CO2 resolution: 0~69mmHg: 0.1mmHg 70~150mmHg CO2 accuracy: 0.25mmHg CO2 accuracy: 0~40mmHg: ±2mmHg 41~70mmHg: ±5 percent 71~100mmHg: ±8 percent 101~150mmHg CO2 accuracy: ±10 percent AwRR accuracy: ±1 rpm Apnea alarm: yes. |
| IBP | Channel: dual-channel label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measurement and warning range: -10~300 mmHg Resolution: 1 mmHg Precision: ±2% or 1 mmHg, whichever is higher Power supply: AC 100-240V, 50/60Hz Safety classification: Class I, CF defibrillation-proof component added. |
| ECG | Lead mode: 3-lead or 5-lead Lead selection: I, II, III, aVR, aVL, aVF, V Waveform: 5-lead, 2-lead, 1-lead Gain: 2,5mm / mV, 5,0mm / mV, 10mm / mV, 20mm / mV, 40mm / mV Scanning speed: 12,5mm / s, 25mm / s, 50mm / s |
| HR: | Measurement and alarm range: 15~350bpm Precision: ±1% or ±1bpm, whichever is higher alarm accuracy: ± 2bpm Resolution: 1bpm ST-segment monitoring: measurement and alarm range: -2.0mV~+2.0mV Precision: -0.8mv~+0.8mv ±0.04mv or ±10%, whichever is higher Other range: unspecified arrhythmic analysis: ASYSTOLE, VFIB / VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACH |
| RESPIRATION | Method: R-F(RA-LL) Respiration rate: measurement and alarm range: 0~150rpm Resolution: 1 rpm Respiration accuracy: ±2 rpm Alarm accuracy: ±3 rpm Apnea alarm: 10~40s Scanning speed: 6.25 mm / s, 12.5 mm / s, 25 mm / s. |
| NIBP | Method: Oscillometry Mode: Manual / AUTO / Continuous Measurement period in AUTO mode: 1/2/3/4/5/10/15/60/90/120/240/480/960 minutes Continuous mode measurement interval: 5 minutes Measurement and warning range: 10 ~ 270 mmHg Resolution: 1 mmHg Cuff stress accuracy: ±3 mmHg Measurement accuracy: maximum mean deviation: ±5 mmHg Maximum standard deviation: 8 mmHg Over-pressure protection: adult mode |
| SpO2 | Measurement and warning range: 0 ~ 100 percent resolution: 1 percent accuracy of measurement: 70 percent ~100 percent: ±2 percent; 0 percent ~69 percent: unspecified. |
| PR | Measuring and alarm range: 30 ~ 250 bpm Measuring accuracy: ±2 bpm or ±2%, whichever is higher |
| TEMP | Channel: dual-channel Measurement and alarm range: 0 ~ 50ºC Resolution: 0.1 ºC Accuracy: ±0.1 ºC |
| EtCO2 | Method: Sidestream or Mainstream CO2 measurement range: 0~150mmHg CO2 resolution: 0~69mmHg: 0.1mmHg 70~150mmHg CO2 accuracy: 0.25mmHg CO2 accuracy: 0~40mmHg: ±2mmHg 41~70mmHg: ±5 percent 71~100mmHg: ±8 percent 101~150mmHg CO2 accuracy: ±10 percent AwRR accuracy: ±1 rpm Apnea alarm: yes. |
| IBP | Channel: dual-channel label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measurement and warning range: -10~300 mmHg Resolution: 1 mmHg Precision: ±2% or 1 mmHg, whichever is higher Power supply: AC 100-240V, 50/60Hz Safety classification: Class I, CF defibrillation-proof component added. |
| Type | Pathological Analysis Equipment |
| Brand Name | CONTEC |
| Place of Origin | Hebei, China |
| Model Number | ECG1200G |
| Instrument classification | Class II |
| Name | CONTEC ECG |
| Trade | Trade assurance service provided |
| Weigh | 3.2Kg |
| Dimension | 340mm(L) * 320mm(W) * 85mm(H) |
| Power supply | AC/DC |
| AC | 100V~240V(50/60Hz) |
| DC | 14.8V/3500mAh rechargeable lithium battery |
| Paper size | 210mm(W)*20m(L) |
| Certificate | CE ISO FDA |
| Type | Pathological Analysis Equipment |
| Brand Name | CONTEC |
| Place of Origin | Hebei, China |
| Model Number | ECG1200G |
| Instrument classification | Class II |
| Name | CONTEC ECG |
| Trade | Trade assurance service provided |
| Weigh | 3.2Kg |
| Dimension | 340mm(L) * 320mm(W) * 85mm(H) |
| Power supply | AC/DC |
| AC | 100V~240V(50/60Hz) |
| DC | 14.8V/3500mAh rechargeable lithium battery |
| Paper size | 210mm(W)*20m(L) |
| Certificate | CE ISO FDA |
| Brand Name | CONTEC |
| Model Number | ECG300G |
| Place of Origin | Hebei, China |
| Instrument classification | Class II |
| Type | Examination Therapy Equipment |
| Certificate | CE ISO FDA SFDA ROHS |
| Product name | 12 Lead ECG 3 channel |
| Weigh | 1.6Kg |
| Dimension | 315mm(L) *215mm(W) * 77mm(H) |
| Display | 3.5″ TFT Color LCD display |
| Optional | The software which can transfer data to PC |
| Multi-language | interface and report |
| Product Name | Fetal Doppler |
| Brand | Contec |
| Model | Sonoline A |
| Anti-electroshock Type | Internally powered equipment |
| Voltage | DC 3 V |
| Power Consumption | < 1W |
| Power Supply | TWO 1.5V(AA size)alkaline battery |
| FHR Measuring Range | 50~240BPM (BPM: beat per minute) |
| Nominal Frequency | 2.0 MHz |
| Working Frequency | 2.0MHz ± 10% |
| Ultrasound Output Power | P < 20 mW |
| Negative Peak Sound Pressure | P_ < 1 MPa |
| Working Mode | Continuous wave doppler |
| Dimension | 135 mm(L) × 95 mm(W) × 35 mm(H) |
| Weight | About 180 g (including batteries) |
| Type | Visual Acuity Examination Apparatus |
| Brand Name | CONTEC |
| Place of Origin | Hebei, China |
| Model Number | ECG600G |
| Instrument classification | Class II |
| OEM/ODM | Yes |
| Certificate | CE |
| Power supply | AC/DC |
| Product Name | 6 channel electrocardiograph ECG machine |
| Lead | 3/6/12-lead display,12-lead Sync collection |
| Multi-language | interface and report |
| Display | 7″TFT-LCD(touch screen) |
| Product name |
portable oxygen ventilator |
| Brand Name | Chenwei |
| Model Number | CWH-2010 |
| Place of Origin | Jiangsu, China |
| Power | 110 to 220V AC ± 10%, 50 to 60Hz ± 2%, built-in battery for backup |
| Gas source | O² |
| Display | 5.7 inch LCD display |
| Type | portable medical respirator, CE approved ICU ventilator, Breathing Apparatus |
| Waveform display | Pressure-time (optional:Flow-time) |
| Ventilation mode | IPPV, SIMV, SIGH, SPONT and manual (optional: CPAP, PEEP) |
| Working type | Gas driven, electrically controlled |
| Certificates |
CE, ISO9001/13485 |
| Warranty | 1 Year |
| Product Name | Portable Ventilator |
| Model | CWH-2020 |
| Brand | Chenwei-med |
| Operating Panel | English (Standard) |
| Drive | Gas driven |
| Operating | Electronically controlled |
| Application | Applied for child and adult. Used for respiratory depression, respiratory, paralysis, and failure of emergency rescue. Available in-vehicle or portable stretcher. |
| Display | 7 inch LCD |
| Gas source | Pure air or Oxygen |
| Ventilation mode | CVV, SIMV, A/C, SIGH, MANUAL, CPAP |
| Tidal volume | 0~1500ml |
| I:E | 4:1~1:8 |
| Breathing rate | 4-99/min, 4-65/min under SIMV |
| FiO2 | 48%~100% |
| Pressure trigger sensitivity | -2~0kPa , PEEP 0-20cmH2O |
| Monitoring Parameters | Tidal volume, Minute volume, Breathing rate, Airway |
| pressure Alarms | No VT, MV too high (low), Airway pressure too high(low), AC power off, back-up battery too low, audio alarms or prompt hints |
| Power | Battery, AC Power AC 220V/50Hz |
| Battery | ≥ 2 hours |
| Basic configuration requirement | Main body 1 Unit, Oxygen cylinder 3L*1 Unit, Silicon mask/ circuit for medical use *1piece, other accessories used to ensure the basic operating. |
| net weight | 6.5Kg |
| Reserve Condition | Temperature: -10~40degree, Relative humidity<90% |
| Working condition | Temperature: 5~40 degrees. Relative humidity< 80% |
| User manual | English (standard) |
| Product Name | CWH-3010 ICU Ventilator |
| Model | CWH-3010 |
| Applied for | adult and child |
| system | with a high-intelligent control system |
| display | with TFT display for ventilation parameters |
| adjustment | Humidifier with temperature adjustment |
| Power | 220V AC ± 10%, 50 to 60Hz ± 2%, built-in battery for backup |
| Gas source | O², air |
| Ventilation mode | IPPV, SIMV, SIGH, SPONT, CPAP, PEEP, S, T, S/T and manual (optional: Bi-level) |
| Parameter monitoring | Tidal volume, minute volume, frequency, inhaling time, airway pressure, PEEP and O² Concentration |
| Waveform display | Pressure-time (optional: Flowtime, pressure-volume loop) |
| Product name | Anesthesia machine |
| Model Number | CWM-RC |
| Brand Name | CHENWEI |
| Place of Origin | Jiangsu, China |
| Screen | 10 inch LCD touch screen |
| Warranty | 1 Year |
| Certificate | CE ISO |
| Type | Anesthesia Equipments & Accessories |
Sphygmomanometer, Mercury ALPK2
HOT AIR OVEN DSI-300D, DIGISYSTEM (30L)
Berry BM1000B Bluetooth Oximeter
