Product Name | Fetal Monitor |
Model | BT-350 |
Brand | Bistos |
Dimension | 80mm (H) X 330mm (L) X 280mm (D) |
Application | Hospital |
Screen rotating | 180 Degree |
LCD display | 7″ wide TFT color LCD display |
Product Name | High Flow Oxygen Therapy |
Brand | BMC |
Model | H-80A |
Flow Monitoring | Adjustable |
Flow Rate | 2L-80L/min |
Oxygen Concentration Adjustable Range | 21%-100% |
Temperature Output Range | 29c-37c |
Temperature Adjustment Gear | 9 steps |
Screen Size | 3.5 inches |
Trend Review Function | 1, 3, 7 days |
Oxygen Concentration Adjustable Range | 21%-100% |
Oxygen Concentration Monitor | Adjustable |
Temperature Monitoring | Adjustable |
sPEEP Monitoring | Monitorable |
Respiratory Rate Monitoring | Monitorable |
Automatic Filter Replacement Function | Yes, can be set |
Automatic Water Refills Tips | Yes |
Humidity Compensation | 7 step adjustable |
Sleep | 4 step adjustable |
Hot Standby | Yes |
ECG Leads | 12-leads (I, II, III, aVR-L-F, V1-6) |
CMRR | 115 dB |
Sampling Frequency | 500 or 1000 Hz/channel/storage |
A/D Conversion | 24 bit |
Resolution | < 1uV/LSB |
Bandwidth | 0.05 – 150 or 300 Hz depending on the sampling rate |
Pacemaker Detection | Hardware and software correlated detection with digital filter |
Filters | Fully digital high-pass diagnostics filter; digital AC interference adaptive filter (50/60 Hz); digital low-pass filter (applied during display and printing stage) |
Defibrillation Protection | AAMI/IEC standards |
Front-End Performance | ANSI/AAMI IEC 60601-2-25:2011 |
Safety | ANSI/AAMI ES1, Class I CF, CE0476 |
ECG Storage | Internal memory 100 ECGs, an expansion for 1000 additional ECGs (optional) |
Display | 4.3″ backlit LCD color display, displays the ECG waveform in real time |
Thermal Printer | 8 dot/mm; 108mm; Z-fold 150mm paper |
Manual Printing | 3 or 6 channels -5/10/25/50 mm/s |
Automatic Printing | Standard or Cabrera; 3, 3+1, 6 channels |
Patient Demographic, Global Measurements, Optional Interpretation (Glasgow University – Prof. MacFarlane) | |
Keypad | Mechanical keypad with alphanumeric keys and function keys |
Connectivity | USB device, LAN, 802.11g/n Wi-Fi (optional) |
Patient Cable | Standard 15D, 10 electrodes |
Data Export | PDF, XML (optional), GDT (optional), DICOM (optional), HL7 (optional) |
Power Supply | Medical AC power-supply unit (100-240 VAC 50/60 Hz); internal rechargeable battery |
Dimensions | 285 x 204 x 65 mm |
Weight | 1.8kg with battery |
Brand | Curative |
Model | Cavent |
Measured parameter | TEMP, ECG, RESP, NIBP, IBP, SpO2 |
Applications | Intensive care |
Configuration | Portable |
Patient type | Pediatric |
Screen size | 12 in |
ECG | Heart rate display range | 15bpm ~ 350bpm |
Heart rate display accuracy | ± 1% or ± 2bpm, whichever is greater | |
Sweeping speed | 12.5mm/s, 25mm/s, 50mm/s | |
Sensitivity selection | 1/2, 5mm/mV ×1, 10mm/mV ×2, 20mm/mV | |
CMRR | ≥ 89dB | |
RESP | Measuring range | 0rpm~120rpm |
Accuracy | ±5% or ±2 rpm | |
Alarm limits setting range | 0rpm~120rpm | |
TEMP | Measuring range | 25.0℃ ~45.0℃ |
Measuring accuracy | ±0.2℃ | |
Responding time | ≤150s | |
NIBP | Measuring method | Oscillometric Technique |
Measuring range | 0 mmHg~300mmHg | |
Accuracy | Maximal mean difference | ±5 mmHg |
Maximal standard deviation | 8 mmHg | |
Measurement range | Adult | SYS 40 ~ 255 mmHg |
MAP 20 ~ 215 mmHg | ||
DIA 10 ~ 195 mmHg | ||
Pediatric patient | SYS 40 ~ 200 mmHg | |
MAP 20 ~ 165 mmHg | ||
DIA 10 ~ 150 mmHg | ||
Neonate | SYS 40 ~ 135 mmHg | |
MAP 20 ~ 110 mmHg | ||
DIA 10 ~ 95 mmHg | ||
SpO2 | Measuring range | 35%~100% |
Low perfusion capability | 0.4%~5% | |
Accuracy | Not greater than 3% for SpO2 range from 70% to 100% | |
PR | Measuring range | 30bpm~240bpm |
Measuring accuracy | ±2bpm or ±2%, whichever |
DEVICE NAME: | COMPUTERISED ECG, Complete on Trolley |
Model Number: | ClECG 01 |
Brand Name: | BIBEAT LTD |
Origin: | Bangladeshi |
Weight: | 25 Kg |
Warranty: | 24 Months |
DEVICE NAME: | PEDOG01 |
Model Number: | ECG01 |
Brand Name: | BIBEAT LTD |
Origin: | Bangladeshi |
Weight: | 8 Kg (Main Sensor) |
Warranty: | 24 Months |
Type | Pathological Analysis Equipment |
Brand Name | Contec |
Place of Origin | Hebei, China |
Model Number | 8000G |
Instrument classification | Class II |
Product name | Stress test ecg machine |
Lead | Standard 12 leads |
Noise level | ≤15μVp-p |
Safety type | Class II Type CF with defibrillation protection |
ECG | Lead mode: 3-lead or 5-lead Lead selection: I, II, III, aVR, aVL, aVF, V Waveform: 5-lead, 2-lead, 1-lead Gain: 2,5mm / mV, 5,0mm / mV, 10mm / mV, 20mm / mV, 40mm / mV Scanning speed: 12,5mm / s, 25mm / s, 50mm / s |
HR: | Measurement and alarm range: 15~350bpm Precision: ±1% or ±1bpm, whichever is higher alarm accuracy: ± 2bpm Resolution: 1bpm ST-segment monitoring: measurement and alarm range: -2.0mV~+2.0mV Precision: -0.8mv~+0.8mv ±0.04mv or ±10%, whichever is higher Other range: unspecified arrhythmic analysis: ASYSTOLE, VFIB / VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACH |
RESPIRATION | Method: R-F(RA-LL) Respiration rate: measurement and alarm range: 0~150rpm Resolution: 1 rpm Respiration accuracy: ±2 rpm Alarm accuracy: ±3 rpm Apnea alarm: 10~40s Scanning speed: 6.25 mm / s, 12.5 mm / s, 25 mm / s. |
NIBP | Method: Oscillometry Mode: Manual / AUTO / Continuous Measurement period in AUTO mode: 1/2/3/4/5/10/15/60/90/120/240/480/960 minutes Continuous mode measurement interval: 5 minutes Measurement and warning range: 10 ~ 270 mmHg Resolution: 1 mmHg Cuff stress accuracy: ±3 mmHg Measurement accuracy: maximum mean deviation: ±5 mmHg Maximum standard deviation: 8 mmHg Over-pressure protection: adult mode |
SpO2 | Measurement and warning range: 0 ~ 100 percent resolution: 1 percent accuracy of measurement: 70 percent ~100 percent: ±2 percent; 0 percent ~69 percent: unspecified. |
PR | Measuring and alarm range: 30 ~ 250 bpm Measuring accuracy: ±2 bpm or ±2%, whichever is higher |
TEMP | Channel: dual-channel Measurement and alarm range: 0 ~ 50ºC Resolution: 0.1 ºC Accuracy: ±0.1 ºC |
EtCO2 | Method: Sidestream or Mainstream CO2 measurement range: 0~150mmHg CO2 resolution: 0~69mmHg: 0.1mmHg 70~150mmHg CO2 accuracy: 0.25mmHg CO2 accuracy: 0~40mmHg: ±2mmHg 41~70mmHg: ±5 percent 71~100mmHg: ±8 percent 101~150mmHg CO2 accuracy: ±10 percent AwRR accuracy: ±1 rpm Apnea alarm: yes. |
IBP | Channel: dual-channel label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measurement and warning range: -10~300 mmHg Resolution: 1 mmHg Precision: ±2% or 1 mmHg, whichever is higher Power supply: AC 100-240V, 50/60Hz Safety classification: Class I, CF defibrillation-proof component added. |
ECG | Lead mode: 3-lead or 5-lead Lead selection: I, II, III, aVR, aVL, aVF, V Waveform: 5-lead, 2-lead, 1-lead Gain: 2,5mm / mV, 5,0mm / mV, 10mm / mV, 20mm / mV, 40mm / mV Scanning speed: 12,5mm / s, 25mm / s, 50mm / s |
HR: | Measurement and alarm range: 15~350bpm Precision: ±1% or ±1bpm, whichever is higher alarm accuracy: ± 2bpm Resolution: 1bpm ST-segment monitoring: measurement and alarm range: -2.0mV~+2.0mV Precision: -0.8mv~+0.8mv ±0.04mv or ±10%, whichever is higher Other range: unspecified arrhythmic analysis: ASYSTOLE, VFIB / VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2, PVC, TACH |
RESPIRATION | Method: R-F(RA-LL) Respiration rate: measurement and alarm range: 0~150rpm Resolution: 1 rpm Respiration accuracy: ±2 rpm Alarm accuracy: ±3 rpm Apnea alarm: 10~40s Scanning speed: 6.25 mm / s, 12.5 mm / s, 25 mm / s. |
NIBP | Method: Oscillometry Mode: Manual / AUTO / Continuous Measurement period in AUTO mode: 1/2/3/4/5/10/15/60/90/120/240/480/960 minutes Continuous mode measurement interval: 5 minutes Measurement and warning range: 10 ~ 270 mmHg Resolution: 1 mmHg Cuff stress accuracy: ±3 mmHg Measurement accuracy: maximum mean deviation: ±5 mmHg Maximum standard deviation: 8 mmHg Over-pressure protection: adult mode |
SpO2 | Measurement and warning range: 0 ~ 100 percent resolution: 1 percent accuracy of measurement: 70 percent ~100 percent: ±2 percent; 0 percent ~69 percent: unspecified. |
PR | Measuring and alarm range: 30 ~ 250 bpm Measuring accuracy: ±2 bpm or ±2%, whichever is higher |
TEMP | Channel: dual-channel Measurement and alarm range: 0 ~ 50ºC Resolution: 0.1 ºC Accuracy: ±0.1 ºC |
EtCO2 | Method: Sidestream or Mainstream CO2 measurement range: 0~150mmHg CO2 resolution: 0~69mmHg: 0.1mmHg 70~150mmHg CO2 accuracy: 0.25mmHg CO2 accuracy: 0~40mmHg: ±2mmHg 41~70mmHg: ±5 percent 71~100mmHg: ±8 percent 101~150mmHg CO2 accuracy: ±10 percent AwRR accuracy: ±1 rpm Apnea alarm: yes. |
IBP | Channel: dual-channel label: ART, PA, CVP, RAP, LAP, ICP, P1, P2 Measurement and warning range: -10~300 mmHg Resolution: 1 mmHg Precision: ±2% or 1 mmHg, whichever is higher Power supply: AC 100-240V, 50/60Hz Safety classification: Class I, CF defibrillation-proof component added. |
Type | Pathological Analysis Equipment |
Brand Name | CONTEC |
Place of Origin | Hebei, China |
Model Number | ECG1200G |
Instrument classification | Class II |
Name | CONTEC ECG |
Trade | Trade assurance service provided |
Weigh | 3.2Kg |
Dimension | 340mm(L) * 320mm(W) * 85mm(H) |
Power supply | AC/DC |
AC | 100V~240V(50/60Hz) |
DC | 14.8V/3500mAh rechargeable lithium battery |
Paper size | 210mm(W)*20m(L) |
Certificate | CE ISO FDA |
Type | Pathological Analysis Equipment |
Brand Name | CONTEC |
Place of Origin | Hebei, China |
Model Number | ECG1200G |
Instrument classification | Class II |
Name | CONTEC ECG |
Trade | Trade assurance service provided |
Weigh | 3.2Kg |
Dimension | 340mm(L) * 320mm(W) * 85mm(H) |
Power supply | AC/DC |
AC | 100V~240V(50/60Hz) |
DC | 14.8V/3500mAh rechargeable lithium battery |
Paper size | 210mm(W)*20m(L) |
Certificate | CE ISO FDA |
Brand Name | CONTEC |
Model Number | ECG300G |
Place of Origin | Hebei, China |
Instrument classification | Class II |
Type | Examination Therapy Equipment |
Certificate | CE ISO FDA SFDA ROHS |
Product name | 12 Lead ECG 3 channel |
Weigh | 1.6Kg |
Dimension | 315mm(L) *215mm(W) * 77mm(H) |
Display | 3.5″ TFT Color LCD display |
Optional | The software which can transfer data to PC |
Multi-language | interface and report |
Product Name | Fetal Doppler |
Brand | Contec |
Model | Sonoline A |
Anti-electroshock Type | Internally powered equipment |
Voltage | DC 3 V |
Power Consumption | < 1W |
Power Supply | TWO 1.5V(AA size)alkaline battery |
FHR Measuring Range | 50~240BPM (BPM: beat per minute) |
Nominal Frequency | 2.0 MHz |
Working Frequency | 2.0MHz ± 10% |
Ultrasound Output Power | P < 20 mW |
Negative Peak Sound Pressure | P_ < 1 MPa |
Working Mode | Continuous wave doppler |
Dimension | 135 mm(L) × 95 mm(W) × 35 mm(H) |
Weight | About 180 g (including batteries) |
Type | Visual Acuity Examination Apparatus |
Brand Name | CONTEC |
Place of Origin | Hebei, China |
Model Number | ECG600G |
Instrument classification | Class II |
OEM/ODM | Yes |
Certificate | CE |
Power supply | AC/DC |
Product Name | 6 channel electrocardiograph ECG machine |
Lead | 3/6/12-lead display,12-lead Sync collection |
Multi-language | interface and report |
Display | 7″TFT-LCD(touch screen) |
Product name |
portable oxygen ventilator |
Brand Name | Chenwei |
Model Number | CWH-2010 |
Place of Origin | Jiangsu, China |
Power | 110 to 220V AC ± 10%, 50 to 60Hz ± 2%, built-in battery for backup |
Gas source | O² |
Display | 5.7 inch LCD display |
Type | portable medical respirator, CE approved ICU ventilator, Breathing Apparatus |
Waveform display | Pressure-time (optional:Flow-time) |
Ventilation mode | IPPV, SIMV, SIGH, SPONT and manual (optional: CPAP, PEEP) |
Working type | Gas driven, electrically controlled |
Certificates |
CE, ISO9001/13485 |
Warranty | 1 Year |
Product Name | Portable Ventilator |
Model | CWH-2020 |
Brand | Chenwei-med |
Operating Panel | English (Standard) |
Drive | Gas driven |
Operating | Electronically controlled |
Application | Applied for child and adult. Used for respiratory depression, respiratory, paralysis, and failure of emergency rescue. Available in-vehicle or portable stretcher. |
Display | 7 inch LCD |
Gas source | Pure air or Oxygen |
Ventilation mode | CVV, SIMV, A/C, SIGH, MANUAL, CPAP |
Tidal volume | 0~1500ml |
I:E | 4:1~1:8 |
Breathing rate | 4-99/min, 4-65/min under SIMV |
FiO2 | 48%~100% |
Pressure trigger sensitivity | -2~0kPa , PEEP 0-20cmH2O |
Monitoring Parameters | Tidal volume, Minute volume, Breathing rate, Airway |
pressure Alarms | No VT, MV too high (low), Airway pressure too high(low), AC power off, back-up battery too low, audio alarms or prompt hints |
Power | Battery, AC Power AC 220V/50Hz |
Battery | ≥ 2 hours |
Basic configuration requirement | Main body 1 Unit, Oxygen cylinder 3L*1 Unit, Silicon mask/ circuit for medical use *1piece, other accessories used to ensure the basic operating. |
net weight | 6.5Kg |
Reserve Condition | Temperature: -10~40degree, Relative humidity<90% |
Working condition | Temperature: 5~40 degrees. Relative humidity< 80% |
User manual | English (standard) |
Product Name | CWH-3010 ICU Ventilator |
Model | CWH-3010 |
Applied for | adult and child |
system | with a high-intelligent control system |
display | with TFT display for ventilation parameters |
adjustment | Humidifier with temperature adjustment |
Power | 220V AC ± 10%, 50 to 60Hz ± 2%, built-in battery for backup |
Gas source | O², air |
Ventilation mode | IPPV, SIMV, SIGH, SPONT, CPAP, PEEP, S, T, S/T and manual (optional: Bi-level) |
Parameter monitoring | Tidal volume, minute volume, frequency, inhaling time, airway pressure, PEEP and O² Concentration |
Waveform display | Pressure-time (optional: Flowtime, pressure-volume loop) |
Product name | Anesthesia machine |
Model Number | CWM-RC |
Brand Name | CHENWEI |
Place of Origin | Jiangsu, China |
Screen | 10 inch LCD touch screen |
Warranty | 1 Year |
Certificate | CE ISO |
Type | Anesthesia Equipments & Accessories |
WRIST BRACE WITH THUMB SUPPORT