Frequency response | 05 Hz to 150 Hz with notch at 50Hz |
Filter | DSP |
Input impedance | 10 MΩ |
Time constant | > 3.2 sec |
A/D conversion | 12 bit |
Noise | < 20μV |
p-p | |
Leakage current | < 10 μA |
Patient isolation | Optical isolation |
Gain | 5, 10 & 20 mm/mV selectable. |
CMRR | > 120 dB |
Sweep speed | 25.0 mm/S. |
Accuracy of HR | +/- 2 BPM. |
Sampling Frequenc | 250 samples per second simultaneous |
Power | 230V/220, 50Hz, 15A |
Power consumption | 1.5KVA |
Incline Range | 0-22% |
Dimension | L X W – 2055 X 750 mm |
Walking Area | 1440 X 500mm |
Weight | 100Kg |
Patient Weight | Up to 250kg |
Belt Speed | Smooth, 0-15Kmph |
Frequency response | 05 Hz to 150 Hz with notch at 50Hz |
Filter | DSP |
Input impedance | 10 MΩ |
Time constant | > 3.2 sec |
A/D conversion | 12 bit |
Noise | < 20μV p-p |
p-p | |
Leakage current | < 10 μA |
Patient isolation | Optical isolation. |
Gain | 5, 10 & 20 mm/mV selectable. |
CMRR | > 120 dB |
Sweep speed | 25.0 mm/S. |
Accuracy of HR | +/- 2 BPM. |
Sampling Frequency | 250 samples per second simultaneous |
Storage | 12 lead unaveraged ECG, 10-second Rhythm strips of 12 leads, Medians after every 8 sec along with HR, BP and fiducial points, full disclosure of entire test |
Power | 230V/220, 50Hz, 15A |
Power consumption | 1.5KVA |
Incline Range | 0-22% |
Dimension | L X W – 2055 X 750 mm |
Walking Area | 1440 X 500mm |
Weight | 100Kg |
Patient Weight | Up to 250kg |
Belt Speed | Smooth, 0-15Kmph |
Instrument Specifications | |
Dimension (W X H X D) | 200mm x 90mm x 65mm |
Weight | 250 gm(approx.) |
Flow Meter | |
Method | Bi-direction digital turbine |
Flow Detection | Opto-electronic Semiconductor Sensor |
Volume Range | 8 liters BTPS |
Flow Range | 0.03 – 14 i/s BTPS |
Flow Resistance | < 7mm of H2O/I/s @ 12 l/s |
Accuracy | : +3% |
User Selectable Predicted Values: | ERS93, Knudson83, ITS White, ITS black, LAM, Barcelona,Indian, User programmable, LLN, KAMAT etal |
Test Method: | FVC, SVC, MVV tests conducted sequentially/optionally |
Internet Connectivity | |
Remote Review | Dedicated SpiroWinView Software |
Upload Method | Test file sent as e-mail Attachment |
PC* Specifications | |
Operating System | Windows* 7/8/10 |
CPU | Intel* Celeron* 1.8GHz or better |
HDD | Minimum of 500 GB |
RAM | Minimum of 2 GB |
Printer | Any Windows* compatible Inkjet / Laser Jet Printer |
CD-ROM | 16 X and above (for installation) |
Mouse | PS2/USB Mouse |
Technical Specifications | |
Sensor | Flow Sensor Bi-directional Digital Turbine |
Flow Range | +16 Ltr/Sec BTPS |
Accuracy | +3% |
Volume Range | +8 Ltr |
Standard Accessories | |
SpiroWin Hardware unit | 1 No. |
Pneumotch | 1 No. |
Software CD | 1 No. |
Pediatric Adaptor | 1 No. |
Pediatric Mouthpieces | 25 Nos. |
Adult Mouthpieces | 25 Nos. |
Power Requirements | |
Voltage | 5V DC |
Frequency | 50 Hz |
Power Consumption | 500 mA maximum |
Physical Characteristics | |
Instrument Dimensions | 50 mm x 100 mm x 25 mm |
Approximate instrument Weight | 0.25 kg |
Environmental Requirements | |
Operating and Storage Temperatures | 10 C to 45 C |
Ambient Relative Humidity | 15% to 90%,non-condensing |
Pressure / Altitude | |
Operating and Storage | 523mmHg to 760 mmHg |
Supply voltage | 220 VAC (+ 10%) |
Weight limit | 10 kg |
Display resolution | 5g |
Accuracy | 2 g |
Dimension | 103x64x162 cm |
Weight incubator | 59 kg |
Air mode control range | 20-39 C |
Dimensions( W,D,H,W ) | 26.4″, 29.5″, 60″ to 74″ |
Air Temp Display | 12C to 44C |
Skin Temp Display | 12oC to 44oC |
Noise Level | < 50 db (A) |
Screen | 5.1“ Integrated LCD Display |
Lamp Usage | 2000 hours |
Lamp Type | 16 pcs Blue Light Fluorescent Tubes |
Intensity | 3 mW/cm² |
Spectral Irradiance | 420 nm to 500 nm |
IV Pole Weight Limit | 6.6 lb (3kg) |
Monitor Shelf Weight Limit | 13.20 lb (6kg) |
Supply Voltage | 220 V± %10, 50Hz |
Power | 600 W |
Total weight | 178lbs/ (81kg) |
Frequency Response | 0.5~40Hz |
Sweep Speed(mm/sec) | 12.5, 25, 50 |
Heart Rate Range | 0~350bpm |
Heart Rate Accuracy | ±1% |
Respiration Rate Measurement Range | : 0~120bpm |
Respiration Rate Accuracy | ±1bpm or 5%(choice max) |
Respiration Rate Resolution | 1bpm |
CO2 Measurement Range | 0~10.0% |
CO2 Accuracy | ±2mmHg or 5%(choice max) |
CO2 Response Time | 180ms |
Frequency response | Monitor: 0.5~40 Hz |
Heart rate range | 0-350 BPM |
Heart rate accuracy | ± 1 % |
ST segment deviation analysis | -0.8~+0.8mV |
ST accuracy | ±0.02mv |
SPO2 measurement range | 0 – 100 % |
Accuracy | ±2% at 70~100% |
Temperature | 5~40 ℃ -20~70 ℃ |
Relative humidity | ≤ 80% ≤ 95% |
Input | 98-260 V AC, 50/60Hz |
Consumption | ≤ 80VA |
Brand Name | OLYMPUS |
Model | CV-260 |
Repair Service Circle | 3-5 working days. |
Name | OLV-10L Oxygen Concentrator |
Secondary Name | Oxygen Concentrator |
Code | OLV-10L |
Type | Standard |
Brand | olive |
Category | Medical Equipment |
Price | ৳88,400 |
Tax Rate | No Tax |
Tax Method | Exclusive |
Unit | pc (pc) |
In Stock | Yes |
Country of Origin : | China |
Model | KJR-Y51W |
Flow rate | 0-5L/min |
Oxygen purity | 93±3% |
Molecular sieve | Brand: CECA, Original: France |
Air compressor | Brand: FESTO ,Original: USA |
Power Supply | AC220V (±10%), 50/60Hz (±1Hz) |
Noise level | ≤45db |
LCD display | present working time, total working time, presetting time, flowrate data, purity data |
Alarm | fliter-clean reminder, built-in power failure ala |
Size | 345mm ×280mm ×558mm |
Net weight | 15.5kgs~ 17.5kgs |
Opitional config. | Nebulization function |
Brand Name | Chenwei |
Model Number | Beta 12 |
Place of Origin | Guangdong, China |
Product name | 15inch patient monitor |
Standard | ECG, SPO2, NIBP, Temp, Resp., HR |
Optional | EtCO2, 2IBP, Massimo SPO2, Printer, etc. |
Display | 12.1 inch TFT screen |
Optional Accessories | Aluminum trolley, wall mount stand |
Size | 300*170*305 mm |
Warranty | 1 Year |
Certificate | CE ISO |
Type |
Examination Therapy Equipment |
Brand Name | Chenwei |
Model Number | Beta 15 |
Place of Origin | Guangdong, China |
Product name | 15inch patient monitor |
Standard | ECG, SPO2, NIBP, Temp, Resp., HR |
Optional | EtCO2, 2IBP, Massimo SPO2, Printer, etc. |
Display | 15 inch TFT screen |
Optional Accessories | Aluminum trolley, wall mount stand |
Size | 300*170*305 mm |
Warranty | 1 Year |
Certificate | CE ISO |
Type |
Examination Therapy Equipment |
Features
|
Product | PC Based ECG |
Brand | BRITEMED |
Patient Leads: | 12 -lead electrocardiogram |
Sensitivity: | 5, 10, 20,40mm/mV |
Sampling Rate: | 1000 samples per second |
Low Cut Filter: | 0.05 Hz, 0.15 Hz, 0.3 Hz |
High Cut Filter: | 30 Hz, 150 Hz, 250 Hz, off |
Hum Filter: | 50 Hz, 60 Hz, off |
Common Mode Rejection: | > 90dB |
Sweep Speed: | 25mm/s |
Printing Paper Size: | A4 |
HR Measurement Range: | 30BPM_300BPM, Accuracy: ± 1BPM |
Defibrillator Protection: | Yes |
Pacing Pulse Detection: | Yes |
Power Supply: | 5V/0.3A (supplied from PC via USB cable) |
Dimensions (L x W x H): | 85 x 60 x 23.2mm |
Weight: | 157.5 g |
Operating Temperature: | 10°C_40°C |
Storage Temperature: | -20°C_50°C |
System Requirements OS: | Microsoft Windows 7 (32-bit/64-bit) or newer OS is required. |
PC display resolution: | 1280 x 768 (min) |
Product Specification | |
Brand | Pentax |
Place of Origin | Japan |
Model | Varsa |
Video Output | Y/C, DVI, RGB, SYNC, AV |
Light Source | LED |
Dimensions | 452 x 167 x 146 mm |
Weight | 11.5 Kg |
Color Tone Adjustment | “R”,”B” adjustment +-25 steps |
Brightness adjustment | “Y” adjustment +-25 steps |
Freeze, Save, Review | Available |
Gain Control | Off, 1, 2, 3 |
Monitoring Mode | Average, Peak |
White balance adjustment | Available |
Voltage | 100-140 VAC |
Frequency | 50-60 Hz |
Specification | |
Brand | PHILIPS |
Model | Digitrak XT |
ECG | 5 Lead, 3 Channel |
Sample Rate | 175/sec |
Event Switch | Press Enter |
Frequency Response | 0.05Hz to 60Hz, @-3dB |
Pacemaker Detection | Available |
Recording Time | Up to 96 Hours |
Weight with Battery | 70 g |
Operating Temperature | 0°C to +45°C/32°F to 113°F |
Waterproof | Yes |
Specification | |
Brand | PHILIPS |
Model | Efficia CM12 |
Display Size | 12″ LCD |
Resolution | 1280 x 800 |
Basic Parameter | ECG, SPO2, NIBP |
Temperature Range | 0–40°C (32–104°F) |
Humidity Range | 15–95% Relative Humidity |
Ingress Protection | IP21 |
Power Consumption | < 75 Watts. |
Weight | < 5.0 kg (11.0 lb). |
Indicator | Alarm, ON, Error, External Power & Battery |
USB 2.0 & RS232 | Available |
ETCO2 | Optional |
IBP | Optional |
Cardiac Output (CO) | Optional |
Specification | |
Brand | PHILIPS |
Model | Efficia DFM100 |
Mode | Biphasic Truncated Exponential |
Charge Time | < 6 seconds |
Patient Impedance Range | Min. 25 ohm |
Delivered Energy Accuracy | ±10% or ±1J whichever is greater |
AED Mode | 150 Joules for Adult & 50 J for Infant/Child |
ECG | 5 Lead |
Display | 7 Inch LCD |
Resolution | 800 x 480 pixels |
Weight | 5.66 Kg |
Report Print | Auto |
SPO2 Range | 0-100% |
Temperature | 0 °C to 45°C |
Humidity | Up to 95% |
Power | 220 V 50 Hz |
Specification | |
Brand | PHILIPS |
Model | IntelliVue MX 430 |
Country of Origin | Germany |
Display Size | 12″ LCD |
Resolution | 1280 x 800 |
Basic Parameter | ECG, SPO2, NIBP |
Temperature Range | 0–40°C (32–104°F) |
Humidity Range | 15–95% Relative Humidity |
Ingress Protection | IP21 |
Power Consumption | <70 W average |
Weight | 6.6 kg (14.6 lb) |
Indicator | Alarm, ON, Error, External Power & Battery |
USB 2.0 & RS232 | Available |
ETCO2 | Optional |
IBP | Optional |
Cardiac Output (CO) | Optional |
Specification | |
Brand | PHILIPS |
Model | PageWriter TC20 |
Warranty | 1 Year |
Display | 6.5″ Touch Screen |
Resolution | 640×480 |
Printing Resolution | 200×500 dpi |
Printing Paper Size | A4 |
Algorithm | DXL ECG |
Interpretive Statement | More Than 600 |
Graphical ST Presentation | Available |
Weight | 8.6 Kg Including Battery |
Product Name | Respironics Bipap Machine |
Brand | Philips |
Modes | AVAPS-AE mode |
Usage/Application | Hospital |
Model Name/Number | A40 |
Ventilation modes | CPAP, S, S/T, PC, T, AVAPS-AE, |
Target tidal volume | 200 – 1500 ML |
Breath rate | 0 – 40 bpm |
Rise time | 1(100ms) – 6 (600ms) |
Humidification | System One humidity control and ‘Dry Box’ technology |
Hybrid ventilation | AVAPS (Average Volume Assured Pressure Support) |
AVAPS rate | 0.5 to 5 cm H2O/min |
Inspiratory time | 0.5 to 3 sec |
Alarms | Patient disconnection, apnea, low minute ventilation, low tidal volume, high respiratory rate |
Monitoring | Pressure, tidal volume, minute ventilation, respiration rate, leak |
Filters | Foam and optional ultra-fine |
Data Management | EncorePro 2 and DirectView software Compatible with oximetry module, Advanced detection of residual respiratory events (Apnea/Hypopnea Index, Obstructed Airway Apnea, Clear Airway Apnea, Hypopnea, Periodic Breathing, RERA, Large Leak and Snore) |
DC power source | 12VDC, 5.0 A |
External battery | 24VDC, 4.2 A |
Battery backup | 11 hours at IPAP 15 / EPAP 4 cm H2O and 12 BPM |
Noise level | 30 dBa AT 10 cm water |
IPAP | 4-40cm H2O |
EPAP | 4-25 cm H2O |
Battery backup | 9hrs |
Warranty | 1 Years |
Product Name | Philips Respironics Ventilator |
Model | Trilogy 100 |
Brand | Philips |
Environmental | |
Temperature | 5°C – 40°C |
Relative humidity | 15% – 95% |
Atmospheric pressure | 110 kPa to 60 kPa |
Physical | |
Weight | 11 lbs, 5 kgs |
Size | 6.6″L x 11.2″W x 9.3″H (16.68 cm L x 28.45 cm W x 23.52 cm H) |
Controls | |
Circuit types | Active with PAP, passive |
Ventilation types | Volume control, pressure control, bilevel |
Volume modes | AC, SIMV (w/PS), CV |
Pressure modes | CPAP, S, S/T, T, PC-SIMV (w/PS) |
IPAP | 4 – 50 cm H20 |
EPAP | 0 – 25 cm H20 for active circuits |
4 – 25 cm H20 for passive circuits | |
CPAP | 4 – 20 cm H20 for passive circuits |
PEEP | 0 – 25 cm H20 for active circuits |
4 – 25 cm H20 for passive circuits | |
Pressure support differential | 0 – 30 cm H20 |
Measured patient parameters | |
Tidal volume | 50 – 2000 ml |
Breath rate | 0 – 60 for AC mode |
1 – 60 for all other modes | |
Inspiratory time | 0.3 – 5.0 secs |
Rise time | 1 – 6 |
Ramp start pressure | 0 – 25 cm H20 for active circuits |
4 – 25 cm H20 for passive circuits | |
4 – 19 cm H20 in CPAP mode | |
Ramp length | Off, 5 – 45 minutes |
Flex | Off, 1 – 3 |
Flow trigger sensitivity | 1 – 9 l/min |
Flow cycle | 10% – 40% |
Apnea rate | 4 – 60 BPM |
Tidal volume | 0 – 2000 ml |
Minute ventilation | 0 – 99 l/min |
Leak rate | 0 – 200 l/min |
Respiratory rate | 0 – 80 BPM |
Peak inspiratory flow | 0 – 200 l/min |
Peak inspiratory pressure | 0 – 99 cm H20 |
Mean airway pressure | 0 – 99 cm H20 |
Percentage patient triggered breaths | 0 – 100% |
9.9:1 to 1:9.9 | |
Alarms | |
Circuit disconnect | Off, 10 – 60 secs |
Apnea | Off, 10 – 60 secs |
High tidal volume | Off, 50 – 2000 ml |
Low tidal volume | Off, 50 – 2000 ml |
High minute ventilation | Off, 1 – 99 l/min |
Low minute ventilation | Off, 1 – 99 l/min |
High respiratory rate | Off, 4 – 80 BPM |
Low respiratory rate | Off, 4 – 80 BPM |
Product Name | Autoclave Machine |
Model | HY-230 |
Chamber size | (diameter * Depth) 230mm * 410mm |
Overall size | (Weight: 340mm, Height: 600mm, Diameter: 420mm |
Chamber Capacity | 16.6 liter |
Power Consumption | 220V / 0.9KW/3.7 Amp. |
Timer Range | 0~60 minutes |
Material Quality | Chamber SUS#304 |
Using Temperature/Pressure | Unwrapped: 122 C/1.4kg/cm2, Wrapped: 122 C/1.4kg/cm2, Liquids: 121 C/1.2kg/cm2 |
Working range | 140 C at 1.5kg/cm2 |
Safety Device | Thermostat control – prevent overheating safety valve, release valve, emergency exhaust valve |
Standard Accessories | #304 Stainless Steel , Sterilization box size: 35cm x 18cm x 12cm tray – 1pc. |
Origin | Taiwan |